S-7780A
4. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
17
4-2. Switching the 4-digit display
・
The 4-digit display can be changed to one of the following five statuses
*1
each time the key is pressed.
Stitch no. display or no display -> Speed display -> Counter display -> Locus display -> (Program display)
*1: The display switches to program display only when memory switch No. 470 is set to “1”.
(Refer to the Service Manual for details on changing memory switch No. 470.)
・
When the speed display or counter display appears, you can press the key to switch to another display.
Display mode
4-digit display
Stitch number
display
ON
ABCD stitch number display
Sewing speed
display
ON
Maximum sewing speed setting
value
ON ON
Backtack sewing speed setting
value
Counter display
ON
Lower thread counter value
Flashing
Lower thread counter warning
enabled
ON
ON
Production counter value
ON ON
Needle replacement counter
value
Flashing
Flashing
Needle replacement counter
warning enabled
Locus display
ON
Locus setting value
Program
display
ON
Program number or setting
parameters
4-3. Setting the sewing speed
4-3-1. Setting the maximum sewing speed
1
Press the key so that the indicator illuminates.
・
The maximum sewing speed setting value will appear in the 4-digit
display.
2
Press the C
/D
keys to change the setting value.
・
When the D key is pressed, the setting increases by 100.
・
When the C key is pressed, the setting decreases by 100.
NOTE:
The setting range is from 220 to 4000 sti/min.
1355D
1356D