II-12
Removing the roller holder ASSY and thermal head ASSY
When handling the thermal head ASSY, do not touch the thermal head by hand. Otherwise, it may
be damaged due to the electricity charged in your body.
(1)
After taking off the retaining ring, remove the roller holder ASSY and the roller holder return
spring from the frame ASSY.
(2)
Remove a screw which secures the thermal head ASSY to the frame ASSY, then take out
the thermal head ASSY.
Fig. 2.2-7 Removing the Roller Holder ASSY
Fig. 2.2-8 Removing the Thermal Head
Roller holder release spring
Roller holder ASSY
Retaining ring
Frame ASSY
Screw
Frame ASSY
Thermal head ASSY
Содержание P-touch PT-1100
Страница 2: ...SERVICE MANUAL MODEL PT 1100 1130 1170 1180 11Q PT 1250 1160 ST 1150 Heavy Duty LabelerTM ...
Страница 5: ...CHAPTER I SPECIFICATIONS ...
Страница 9: ...I 3 Fig 1 1 2 Key Arrangement 1 ...
Страница 10: ...I 4 Fig 1 1 2 Key Arrangement 2 ...
Страница 11: ...I 5 Fig 1 1 2 Key Arrangement 3 ...
Страница 13: ...CHAPTER II MECHANISMS ...
Страница 50: ...35 II 2 3 4 Troubleshooting Flows 1 Tape feeding failure ...
Страница 51: ...36 II ...
Страница 52: ...37 II 2 Printing failure ...
Страница 53: ...38 II ...
Страница 54: ...39 II 3 Powering failure Nothing appears on the LCD ...
Страница 55: ...40 II 4 No key entry possible ...
Страница 56: ...CHAPTER III ELECTRONICS ...
Страница 75: ...III 17 3 3 3 Troubleshooting Flows 1 Tape feeding failure 2 Printing failure ...
Страница 76: ...III 18 3 Powering failure Nothing appears on the LCD ...
Страница 77: ...III 19 4 Abnormal LCD indication ...
Страница 78: ...III 20 5 No key entry possible 6 Tape cassette type not identified ...
Страница 80: ......
Страница 81: ......
Страница 82: ......
Страница 83: ...Jan 2002 8V2010BE1 Printed in Japan ...