II-41
[
7] Reassembly of the Power Supply PCB Assy
(1) After orienting the inlet assy correctly in the inlet bracket, tighten the two
screws.
Note:
Always mount the inlet assy in the inlet bracket in the direction
shown in the illustration below.
Fig. 2.2-55 Reassembly of the Inlet Assy
(2) Turn the bottom cover over, and set the oblong hole in shield plate B on
the projection on the bottom cover to set shield plate B on the bottom
cover.
(3) After plugging the inlet assy and power supply harnesses into the
connectors on the power supply PCB, set the power supply PCB assy on
the bottom cover, with shield plate B sandwiched inbetween. Then,
tighten the two screws.
Fig. 2.2-56 Reassembly of the Shield Plate B and the Power Supply PCB Assy
Inlet bracket
Two screws
Inlet assy
Inlet harness
Bottom cover
Shield plate B
Power supply PCB assy
Power supply harness
Two screws
Содержание P-touch PRO DX PT-9200DX
Страница 1: ...SERVICE MANUAL MODEL PT 9200DX ...
Страница 2: ...SERVICE MANUAL MODEL PT 9200DX ...
Страница 5: ...CHAPTER I SPECIFICATIONS ...
Страница 11: ...CHAPTER II MECHANISMS ...
Страница 66: ...CHAPTER III ELECTRONICS ...
Страница 89: ...CHAPTER IV TROUBLESHOOTING ...
Страница 92: ...IV 2 2 The tape cassette type is not detected correctly 3 The LED does not light up ...
Страница 93: ...IV 3 4 No printing is performed 5 The interface malfunctions ...
Страница 94: ...IV 4 6 The tape is not cut ...
Страница 95: ...IV 5 7 The tape is not fed correctly ...
Страница 96: ...IV 6 ...
Страница 97: ...IV 7 8 Half cut is not possible ...
Страница 98: ...IV 8 9 The tape is not ejected forcibly ...
Страница 99: ...APPENDIX Circuit Diagram Main PCB Power Supply PCB 100 120V Power Supply PCB 230V ...
Страница 101: ......
Страница 102: ......
Страница 103: ......
Страница 104: ...Sep 2000 5V2106BE0 Printed in Japan ...