V –
46
CNG detection when the
external telephone is connected
with a line in TAD mode
WSW34
(Function setting 12)
Function
Selector
No.
Setting and Specifications
4
5
No. 1
2
3
0
0
0
:
0 sec.
0
0
1
:
1 sec.
0
1
0
:
2 sec.
0
1
1
:
3 sec.
1
0
0
:
4 sec.
1
0
1
:
5 sec.
1
1
0
:
6 sec.
1
1
1
:
7 sec.
1
|
3
No. of CNG cycles to be detected
(when the line is connected via
the external telephone in the
external TAD mode or via the
facsimile equipment in F/T or TAD
mode)
No. 4
5
0
0
:
0.5 (A)
0
1
:
1
(B)
1
0
:
1.5 (C)
1
1
:
2
(D)
Number of DTMF tone signals for
inhibiting the detection of CNG
during external TAD operation
6
7
No. 6
7
0
0
:
3
0
1
:
2
1
0
:
1
1
1
:
OFF
0: Only when the
equipment detects
itself being called
8
1: Always
Erasing time length of ICM tone
recorded preceding the tone
detection starting point in the case
of automatic line disconnection
due to no voice signal received
●
Selectors 1 through 3:
Erasing time length of ICM tone recorded preceding the tone detection
starting point in the case of automatic line disconnection due to no
voice signal received
If the equipment has disconnected the line after detection of disconnection tone in ICM re-
cording, it erases tone recorded preceding the tone detection starting point for the time
length set by these selectors.
●
Selectors 4 and 5: No. of CNG cycles to be detected (For those models equipped with a built-
in TAD)
The equipment interprets a CNG as an effective signal if it detects a CNG signal by the num-
ber of cycles specified by these selectors in any of the following cases:
• when the line is connected via the external telephone in the external TAD mode.
• when the line is connected via the facsimile equipment in F/T or TAD mode.
●
Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during
external TAD operation
If the equipment receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
●
Selector 8:
CNG detection when the external telephone is connected with a line in TAD mode
If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself
being called. If the external telephone is connected with a line before the equipment detects
itself being called, the equipment will no longer detect a CNG signal.
If this selector is set to "1," the equipment will detect a CNG signal every time the external
telephone is connected with a line, even without detecting itself being called.
Содержание MFC 1870MC
Страница 1: ...FACSIMILE EQUIPMENT SERVICE MANUAL MODEL FAX1170 1270 1570MC FAX1010 1020 1030 MFC1770 1870MC 1970MC ...
Страница 4: ...CHAPTER I GENERAL DESCRIPTION ...
Страница 10: ...CHAPTER II INSTALLATION ...
Страница 11: ...CHAPTER III THEORY OF OPERATION ...
Страница 43: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 94: ...CHAPTER V MAINTENANCE MODE ...
Страница 101: ...V 6 Scanning Compensation Data List MFC1970MC Scanning Compensation Data List Other models ...
Страница 148: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Страница 191: ...D Power Supply 100 120V U S A CANADA TAIWAN ...
Страница 192: ...D Power Supply 200 240V EUROPE SOUTH AMERICA ...
Страница 193: ...D Power Supply 200 240V GULF ASIA CHINA ...
Страница 197: ......
Страница 203: ......
Страница 206: ......