WSW31
(Function setting 9)
Function
Selector
No.
Setting and Specifications
Not used.
1
2
5
Default reduction rate for failure
of automatic reduction during
recording
●
Selector 2:
Default reduction rate for failure of automatic reduction during recording
This selector sets the default reduction rate to be applied if the automatic reduction function
fails to record one-page data sent from the calling station in a single page of the current re-
cording paper.
If it is set to "0," the equipment records one-page data at full size (100%) without reduction;
if it is set to "1," the equipment records it at half size (50%).
●
Selector 5:
Minimum short-OFF duration in distinctive ringing
The ringer pattern consists of short and long rings, e.g., short-short-long rings. This selector
sets the minimum OFF duration following a short ring in order to avoid missing ringer tones
in distinctive ringing.
If this selector is set to "1," when the short-OFF duration is a minimum of 90 ms long, then
the equipment will interpret the short-OFF as OFF.
Not used.
0:
130 ms
1:
90 ms
Minimum short-OFF duration in
distinctive ringing
0:
100%
1:
50%
3
4
Not used.
6
|
8
Содержание MFC 1870MC
Страница 1: ...FACSIMILE EQUIPMENT SERVICE MANUAL MODEL FAX1170 1270 1570MC FAX1010 1020 1030 MFC1770 1870MC 1970MC ...
Страница 4: ...CHAPTER I GENERAL DESCRIPTION ...
Страница 10: ...CHAPTER II INSTALLATION ...
Страница 11: ...CHAPTER III THEORY OF OPERATION ...
Страница 43: ...CHAPTER IV DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 94: ...CHAPTER V MAINTENANCE MODE ...
Страница 101: ...V 6 Scanning Compensation Data List MFC1970MC Scanning Compensation Data List Other models ...
Страница 148: ...CHAPTER VI ERROR INDICATION AND TROUBLESHOOTING ...
Страница 191: ...D Power Supply 100 120V U S A CANADA TAIWAN ...
Страница 192: ...D Power Supply 200 240V EUROPE SOUTH AMERICA ...
Страница 193: ...D Power Supply 200 240V GULF ASIA CHINA ...
Страница 197: ......
Страница 203: ......
Страница 206: ......