LH4-B800E
6 - 18
6. ELECTRIC MECHANISM
<1-step power supply circuit board>
CN1
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
P8V (+8V)
The zigzag home position can not be found.
The zigzag mechanism does not operate.
Error E-05 is displayed.
The machine motor does not turn.
2
0V
3
N8V (-8V)
4
OV. det
5
RY. out
6
OV. FAULT
7
+5V
8
PHOTO
9
U
10
V
11
W
12
U
13
V
14
W
15
IPM. FAULT
CN2
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
AC200-R
The zigzag home position can not be found.
The zigzag mechanism does not operate.
Error E-05 is displayed.
The tension release solenoid does not operate.
2
AC200-T
3
-
4
-
CN3
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
AC220-R
The zigzag home position can not be found.
The zigzag mechanism does not operate.
Error E-05 is displayed.
The tension release solenoid does not operate.
2
-
3
AC220-T
4
-
CN4
Pin No.
Signal name
Symptoms resulting mainly from poor contact
1
AC230/240-R
The zigzag home position can not be found.
The zigzag mechanism does not operate.
Error E-05 is displayed.
The tension release solenoid does not operate.
2
-
3
-
4
AC230/240-T
Содержание LH4-B800E