LH4-B800E
4 - 7
4. Adjustment
2
-2
1
13.5
+0.1
0
16
+0.1
0
2
-3
1
12.7
+0.1
0
16.2
+0.1
0
2
805-2
1
14.2
+0.1
0
16.7
+0.1
0
3.2 mm
2.5 mm
q
e
w
r
0.01 - 0.08 mm
Adjusting the clearance between needle and hook point
Loosen the screws
e
and move the rotary hook
r
forward or back until there is a clearance of 0.01 to 0.08 mm
between the needle
q
and the hook point
w
.
Needle plate thickness
Application
Gauge
Clothing
(-2)
K n i t t e d
wear
Knitted
wear
(-3)
Long-hole
specifica-
tions
(-5)
Thin knitted
wear
S13595-001 Gauge 815-2
S13596-001 Gauge 815-3
S13597-001 Gauge 805-2