5-32
Confidential
8.6
MP Tray Cover ASSY/Process Cover ASSY/Emblem cover
(1) Push the front cover release button.
(2) Open Process cover ASSY.
(3) Release the Hook to remove the Process cover stopper.
Fig. 5-25
(4) Remove the MP tray cover ASSY and the Process cover ASSY to the direction of 4a and
4b to release the Pins, and remove them.
Fig. 5-26
1
2
3
Process cover ASSY
MP tray cover ASSY
Process cover stopper
Drive release link
Front cover release button
Hook
Pin
Pin
4a
4b
Process cover ASSY
MP tray cover ASSY
Содержание HL 5370DW
Страница 12: ...CHAPTER 1 SPECIFICATIONS ...
Страница 32: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Страница 57: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 109: ...Confidential CHAPTER 4 PERIODIC MAINTENANCE ...
Страница 129: ...4 19 Confidential 14 Secure the Fuser unit with the pan B M4x20 Taptite screw Fig 4 27 Taptite pan B M4x20 Fuser unit ...
Страница 145: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Страница 153: ...5 6 Confidential Fig 5 3 EM D110 4 places Separation pad ASSY ...
Страница 154: ...5 7 Confidential 5 GEAR LAYOUT DRAWING Fig 5 4 ...
Страница 187: ...5 40 Confidential 2 Remove the SW key B from the Top cover printed ASSY Fig 5 41 SW key B Top cover printed ASSY ...
Страница 200: ...5 53 Confidential 8 13 Main Shield Plate ASSY 1 Remove the Insulation sheet Fig 5 63 Insulation sheet Frame L ...
Страница 212: ...5 65 Confidential 8 24 Gear 17 20 23 1 Remove the Gear 23 Fig 5 84 2 Remove the Gear 20 Fig 5 85 ...
Страница 213: ...5 66 Confidential 3 Remove the Gear 17 black Fig 5 86 4 Remove the Gear 17 white Fig 5 87 ...
Страница 261: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 276: ...Confidential CHAPTER 7 SERVICE MODE ...
Страница 308: ...App 1 1 Confidential FIRMWARE SWITCHES WSW There is not function of the firmware switch in this machine ...