4-2
Confidential
1.1
Periodical Replacement Parts
Periodical replacement parts are the parts to be replaced periodically to maintain product
quality. These parts would affect the product quality greatly if they lost their function even if
they do not appear to be damaged or there is no change in their appearance.
The periodical replacement parts listed below should be replaced at the service center
referring to the service life.
To reset the count of each periodical replacement parts, refer to
*1
At 5% print coverage (A4 or Letter size). The actual number of printed pages will vary
depending on the print jobs and paper you use. The number is calculated when simplex
printed the normal business document (ISO/IEC19752) on the A4 size.
*2
Paper feeding kit MP means the MP roller holder ASSY and the separation pad ASSY MP.
*3
Paper feeding kit for Tray 1, Tray 2 and Tray 3 means the roller holder ASSY, the separation
pad ASSY and the separation pad spring. Tray 1, Tray 2 and Tray 3 are the same kit.
Parts Name
LCD Message
(HL-5380DN)
Qty
Approximate Life
*1
(number of prints)
Replacement
Procedure
Fuser Unit
REPLACE FUSER
1
100,000 pages
See subscription
1.2.1, Chapter 4
Laser Unit
REPLACE LASER
1
100,000 pages
PF kit for Tray 1
*3
REPLACE PF KIT1
1
Except for India:
100,000 pages
See subscription
1.2.2, Chapter 4
India:
80,000 pages
PF kit for Tray 2
*3
REPLACE PF KIT2
1
Except for India:
100,000 pages
India:
80,000 pages
PF kit for Tray 3
*3
REPLACE PF KIT3
1
Except for India:
100,000 pages
India:
80,000 pages
MP PF tray
*2
REPLACE PF KIT MP
1
Except for China/
India: 50,000 pages
See subscription
1.2.3, Chapter 4
China:
25,000 pages
India:
12,000 pages
Note :
• Always turn off the power switch of the printer and unplug the power cord from the
power outlet before replacing the periodical replacement parts.
• If the Fuser Unit is replaced after errors related to the Fuser Unit occur, it is necessary to
leave the printer power ON for ten minutes after part replacement. This will make the
printer to be released from errors.
• After disconnecting flat cables, check that each cable is not damaged at its end or short-
circuited.
• When connecting flat cables, do not insert them at an angle. After insertion, check that
the cables are not at an angle.
• The counter value of PF kit for tray 2 and PF kit for tray 3 does not change, even if the
Optional lower tray 2 and Optional lower tray 3 are replaced.
Содержание HL 5370DW
Страница 12: ...CHAPTER 1 SPECIFICATIONS ...
Страница 32: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Страница 57: ...Confidential CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 109: ...Confidential CHAPTER 4 PERIODIC MAINTENANCE ...
Страница 129: ...4 19 Confidential 14 Secure the Fuser unit with the pan B M4x20 Taptite screw Fig 4 27 Taptite pan B M4x20 Fuser unit ...
Страница 145: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Страница 153: ...5 6 Confidential Fig 5 3 EM D110 4 places Separation pad ASSY ...
Страница 154: ...5 7 Confidential 5 GEAR LAYOUT DRAWING Fig 5 4 ...
Страница 187: ...5 40 Confidential 2 Remove the SW key B from the Top cover printed ASSY Fig 5 41 SW key B Top cover printed ASSY ...
Страница 200: ...5 53 Confidential 8 13 Main Shield Plate ASSY 1 Remove the Insulation sheet Fig 5 63 Insulation sheet Frame L ...
Страница 212: ...5 65 Confidential 8 24 Gear 17 20 23 1 Remove the Gear 23 Fig 5 84 2 Remove the Gear 20 Fig 5 85 ...
Страница 213: ...5 66 Confidential 3 Remove the Gear 17 black Fig 5 86 4 Remove the Gear 17 white Fig 5 87 ...
Страница 261: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 276: ...Confidential CHAPTER 7 SERVICE MODE ...
Страница 308: ...App 1 1 Confidential FIRMWARE SWITCHES WSW There is not function of the firmware switch in this machine ...