2-54
Confidential
Error code BB00
A white level not within the standard was scanned when function code 55 was executed.
Error code BC00
When scanning the fax, white or black correction data for the second side CIS was not within
the correct range. (Second time)
Error code BD00
A black level not within the standard was scanned when function code 55 was executed.
Scanner Error
-
Step
Cause
Remedy
1
Dirt on the second side
document hold
Clean the second side document hold.
2
Dirt on the white tape
Clean the white tape.
3
First side CIS unit failure
Replace the first side CIS unit.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
Second side document hold
failure
Replace the ADF unit.
6
White tape failure
Replace the document scanner unit.
7
Main PCB failure
Replace the main PCB ASSY.
-
Step
Cause
Remedy
1
Incorrect correction data for
second side CIS unit
Execute "Set CIS scan area (
)".
2
Second side CIS unit failure
Replace the second side CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.
Scanner Error
-
Step
Cause
Remedy
1
Dirt on the second side
document hold
Clean the second side document hold.
2
Dirt on the white tape
Clean the white tape.
3
First side CIS unit failure
Replace the first side CIS unit.
4
Second side CIS unit failure
Replace the second side CIS unit.
5
Second side document hold
failure
Replace the ADF unit.
6
White tape failure
Replace the document scanner unit.
7
Main PCB failure
Replace the main PCB ASSY.