3-61
Confidential
9.15 Panel Unit (For models without touch panel)
9.15.1 Panel Unit
(1) Remove the four taptite cup B M3x10 screws.
(2) Release the claws to remove the panel unit. Disconnect the panel harness from the
panel PCB ASSY.
Fig. 3-56
Harness routing: Refer to
.
Note:
• When removing the panel unit, DO NOT pull the panel unit strongly because it is
connected to the panel harness.
Taptite cup B M3x10
Taptite cup B M3x10
Claws
Panel unit
Panel PCB ASSY
Panel harness