Troubleshooting and routine maintenance
83
C
d
Put the print sample in front of the drum
unit, and find the exact position of the
poor print.
e
Turn the drum unit gear by hand while
looking at the surface of the OPC
drum (1).
f
When you have found the mark on the
drum that matches the print sample,
wipe the surface of the OPC drum with a
dry cotton swab until the dust or glue on
the surface comes off.
IMPORTANT
• The drum is photosensitive so DO NOT
touch it with your fingers.
• DO NOT clean the surface of the
photosensitive drum with a sharp object.
• DO NOT use excessive force when
cleaning the drum unit.
g
Put the toner cartridge back into the
drum unit until you hear it lock into place.
If you put the cartridge in correctly, the
blue lock lever will lift automatically.
h
Put the drum unit and toner cartridge
assembly back in the machine.
i
Close the front cover.
j
Plug the machine’s power cord back into
the electrical socket first and then
reconnect all cables. Turn on the
machine.