BES-116AC
144
Chapter 10 Troubleshooting
ERROR E5 to ERROR FF frequently
occur.
• Replace the main PCB with a new one.
All solenoids of head do not operate.
• Refer to the block diagram showing cable connections and check fuse
F2 on the power supply PCB.
If it is blown, replace it with a new one. The 60v circuit is faulty if the
fuse is blown immediately after turning on the power even after
replacing the fuse.
Jump solenoid does not operate.
• Check to see if connection from the jump solenoid to connector P10 of
the head PCB is proper.
• Check the resistance value of the jump solenoid which does not operate
with the connector section. The normal resistance value is
approximately 185
Ω
.
If it is faulty, replace the solenoid with a new one. In this case, the
head PCB may also be faulty. Also replace the head PCB with a new
one if it does not operate properly even after replacing the solenoid.
• Replace the head PCB with a new one.
Pickker solenoid does not operate.
• Check to see if connection from the pickker solenoid to connector P8
of the head PCB is proper.
• Check the resistance value of the pickker solenoid which does not
operate with the connector section. The normal resistance value is
approximately 426
Ω
.
If it is faulty, replace the solenoid with a new one. In this case, the
head PCB may also be faulty. Also replace the head PCB with a new
one if it does not operate properly even after replacing the solenoid.
• Replace the head PCB with a new one.
• Enter the encoder signal test mode and manually turn the main shaft
pulley.
If it is abnormally heavy, the main shaft mechanism is faulty.
• Refer to the block diagram showing the cable connections and check
to see if connection from the main shaft motor to the main PCB is
proper. Also check the connection from connectors P14 of the main
PCB to the 14v terminal of the power transformer.
Main shaft rotation speed error oc-
curs.
• Refer to the block diagram showing the cable connections and check
to see if connection of connector P22 of the main PCB in the control
box is proper.
• Check fuse F3 on the power supply PCB.
If it is blown, replace it with a new one. If it becomes blown again,
the 24v system circuit is faulty.
Exhaust fan motor stops.
Symptom
Measures
Содержание BES-116
Страница 11: ...9 BES 116AC Setting of thread breakage sensor page 78 Setting of Machine page 81 ...
Страница 16: ...14 BES 116AC ...
Страница 17: ...Chapter 1 Preparation of Embroidery Machine ...
Страница 112: ...BES 116AC 110 Chapter 5 Setting ...
Страница 113: ...Chapter 6 Operation of Machine ...
Страница 121: ...Chapter 7 Maintenance ...
Страница 127: ...Chapter 8 Adjustment ...
Страница 136: ...Chapter 8 Adjustment BES 116AC 134 ...
Страница 137: ...Chapter 9 Error code list ...
Страница 148: ...BES 116AC 146 Chapter 10 Troubleshooting ...
Страница 149: ...Connection and Installation of Optional Equipment ...
Страница 152: ...BES 116AC 150 Connection and Installation of Optional Equipment ...
Страница 153: ...INSTRUCTION MANUAL BROTHER INDUSTRIES LTD NAGOYA JAPAN Printed in Japan 155 116 S93116 002 2000 03 H 1 ...