14. ELECTRIC MECHANISM
202
KE-430HX/KE-430HS, BE-438HX/BE-438HS
Error status #7 Error code appears on the display when the foot switch is depressed.
Probable causes
Check/ repair/ adjust
Parts to be replaced
1. If the X feed does not move and
"E200" is displayed, there is a
malfunction of the power PCB.
Disconnect connector P2 (POWER) from the
power supply motor PCB, and then turn on the
power switch and check LD1 (red) on the power
supply motor PCB.
OK if illuminated.
After checking, turn off the power switch, wait for
five minutes or more, and then insert connector
P2 (POWER) into the power supply motor PCB.
Power supply motor PCB
assembly
2. If the X feed does not move and
"E200" is displayed, there is a
malfunction of the main PCB.
a. With LD1 (red) on the main PCB not lit,
disconnect connector P22 (POWER) from the
main PCB, and check the continuity between
terminals 1-3 of P22.
OK if
ohms.
b. Disconnect the relay connector (translucent
and connected to XT12/XT10/XT11/XT8) for
connecting the pulse motor to the main PCB,
and check the continuity between terminals
2-3 and 5-6 of the connector.
OK if
ohms.
c. Insert P22 and the translucent relay connector
for connecting the pulse motor connection to
the main PCB, turn on the power switch and
then check LD1 (red) on the power supply
motor PCB.
OK if illuminated.
If LD1 is illuminated during the check in step 1
in #7 but it does not illuminate when the
translucent relay connector for connecting the
pulse motor and P22 are connected, there is a
malfunction of the main PCB.
d. Check LD1 (red) on the main PCB.
OK if illuminated.
Main PCB assembly
3. If the X feed moves slightly and
"E200" is displayed, there is a
malfunction of the encoder.
a. Check that connector P2 (X-ENC) is inserted
into the main PCB and that the color matches.
b. Check the encoder input while referring to
"4-4. Checking input".
Pulse motor X assembly
Main PCB assembly
4. If the X feed does not move and
"E200" is displayed, there is a
malfunction of the pulse motor and
cord.
a. Disconnect the relay connector (translucent
and connected to XT12/XT10/XT11/XT8) for
connecting the pulse motor to the main PCB,
and measure the resistance between
terminals 2-3 and 5-6 of the cord connector.
OK if 1.89-2.3 ohms (2.1 ohms +/- 10%).
b. If step a. (above) is OK, there is a malfunction
of the main PCB.
Pulse motor X assembly
Main PCB assembly
4178B
4179B
4180B
Содержание BE-438HS
Страница 203: ...14 ELECTRIC MECHANISM 192 KE 430HX KE 430HS BE 438HX BE 438HS 4313B ...
Страница 204: ...14 ELECTRIC MECHANISM 193 KE 430HX KE 430HS BE 438HX BE 438HS 4314B ...
Страница 205: ...14 ELECTRIC MECHANISM 194 KE 430HX KE 430HS BE 438HX BE 438HS 4315B ...
Страница 206: ...14 ELECTRIC MECHANISM 195 KE 430HX KE 430HS BE 438HX BE 438HS 4316B ...