8. LIST OF ERROR CODES
BAS-341H, BAS-342H
55
Data editing-related errors
Code
Cause of error and remedy
E500
The enlargement ratio setting caused the sewing data to extend outside the sewing area.
Set the enlargement ratio again.
Press the RESET key to clear the error.
E502
The enlargement ratio caused the data pitch to exceed the maximum pitch of 12.7 mm.
Press the RESET key to clear the error. Set the enlargement ratio again.
E510
Error in sewing data.
Press the RESET key to clear the error.
If an error occurs while reading or revising the sewing data, revise the data.
E511
No end code has been input into pattern data.
Press the RESET key to clear the error.
E512
Number of stitches exceeds allowed maximum.
Press the RESET key to clear the error.
E520
Extended option output number already exists.
Change the extended option output number.
If not using the extended option output, initialize the data to clear the extended option output data.
E581
Memory switch file cannot be read correctly.
The model for the data which was read does not match the model being written to.
Press the RESET key to clear the error. Read data for the same sewing machine model.
E582
Memory switch versions do not match.
Press the RESET key to clear the error. Read data for the same version.
E583
User program versions do not match.
Press the RESET key to clear the error. Read data for the same version.
Device-related errors
Code
Cause of error and remedy
E600
Upper thread breakage occurred. Thread the upper thread. Re-sewing is then possible.
Turn off the power, and then check that connectors P9 and P36 on the main P.C. board are properly connected.
E670
Problem with the lower thread detector.
Turn off the power, and then check the lower thread detector.