3. INSTALLATION
12
BAS-341H, BAS-342H
NOTE:
Route the X, Y and work clamp pulse motor harnesses so that they do not touch the power supply P.C. board at
the bottom of the control box.
Connectors
Connection location on
main P. C. board
Cord clamps /
cable ties
X pulse motor encoder [5-pin] White
P17 (X-ENC)
(2)
Y pulse motor encoder [5-pin] Blue
P18 (Y-ENC)
(2)
Intermittent presser foot pulse motor encoder [5-pin] Black
P19 (P-ENC)
(2)
Machine head switch [3-pin]
P14 (HEAD-SW)
(2)
Conversion harness [7-pin] White
P15 (PEDAL)
(2)
Machine head memory [6-pin]
P16 (HEAD-M)
(2)
Thread trimmer solenoid [6-pin]
P2 (SOL1)
(1)
Digital tension solenoid / Tension release solenoid [4-pin]
P3 (SOL2)
(1)
X pulse motor [4-pin] White
P21 (XPM)
(1)
Y pulse motor [4-pin] Blue
P22 (YPM)
(1)
Work clamp pulse motor [4-pin] Black
P23 (PPM)
(1)
Home position sensor [12-pin] White
P8 (SENSOR1)
(2) (3)
STOP switch [6-pin] White
P9 (HEAD)
(2) (3)
Valve harness [12-pin]
P35 (EX-OUT1)
(2) (3)
Upper thread breakage detector [2-pin] White
P36, P9(HEAD)
(2) (3)
Fan [6-pin]
P7 (SENSOR2)
(2) (3)
3672B
Lock the cord
clamp securely.
<Removal>
Press the tab.
<Securing>
< Main P. C. board >