200768_1
5
Hearth Requirements
The appliance needs to be located onto a solid non-combustible hearth with a minimum
thickness of 12mm. The hearth must be capable of withstanding the weight of the
appliance.
NB Side measurements taken from the Lid of the stove (Dimension E on page 4):
Rear measurement taken from the dilution box
Ensure all minimum clearances to combustible materials are complied with as
below:
Hearth Protrusion (in front of the appliance)
50mm
Shelf Distance (above the stove)
300mm
The specified minimum clearances provide the minimum distance to combustible
and non-combustible materials. If the appliance is intended to be installed into a non-
combustible opening, the clearances to the sides and above can be reduced.
However it is recommended that the specific minimum clearances are maintained,
irrespective of the materials used in the construction of the opening. This has been
tested and approved, to allow adequate air flow and access to the controls, as well
as allowing access for smoke tests and future maintenance of the flue and the
appliance.
The clearance to the rear of the appliance must always be a minimum of
50mm. Clearances to combustible materials cannot be reduced
Please note the gas supply connection to the appliance is to the right hand side
rear of the stove. The connection requires an 8mm-diameter semi-rigid pipe, not
more than 1 meter in length.
Additional Requirements
Curtains should not be positioned above the appliance at a distance of less than
the minimum specified for shelves
An additional guard is to be used to take account of the special hazards that exist
in nurseries and other places where there are young children or aged or infirm
persons present.