4/21
❖
the data plate (voltage and frequency) correspond to those of the electrical
mains
❖
the electrical power supply/socket is adequate for maximum device
power. If not, contact a qualified technician.
✓
The device should not be used as an activator for water heaters, stoves, etc., nor
should it discharge into hot air/fume vent ducts deriving from any type of
combustion unit. It must expel air outside via its own special duct.
✓
Operating temperature: -20°C up to +50°C.
✓
The device is designed to extract clean air only, i.e. without grease, soot, chemical
or corrosive agents, or flammable or explosive mixtures.
✓
Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
✓
Do not immerse the device or its parts in water or other liquids.
✓
Turn off the main switch whenever a malfunction is detected or when cleaning.
✓
For installation an omnipolar switch should be incorporated in the fixed wiring, in
accordance with the wiring regulations, to provide a full disconnection under
overvoltage category III conditions (contact opening distance equal to or greater
than 3mm).
✓
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
✓
Do not obstruct the fan or exhaust grille to ensure optimum air passage.
✓
Ensure adequate air return/discharge into/from the room in compliance with
existing regulations in order to ensure proper device operation.
✓
If the environment in which the product is installed also houses a fuel-operating
device (water heater, methane stove etc., that is not a “sealed chamber” type
), it is
essential to ensure adequate air intake, to ensure good combustion and proper
equipment operation.
✓
contact with the Test Finger (test probe “B” of the norm EN61032) in compliance
with the current safety regulations.
2.1 Technical specifications
✓
Front cover (A) removable for cleaning without the use of tools.
✓
Inner ventilation unit (B) and wall support base (D) made of high quality, impact
and UV-resistant ABS, colour RAL 9010.
✓
Integrated multi-colour led (C) to obtain a visual feedback of the unit status.
✓
Smart humidity control.
✓
Integral temperature sensor for the automatic management of the inversion time
(comfort mode).
✓
Automatic anti-frost protection to prevent frost building up on the heat exchanger.
✓
Wall support base (D) provided with a ma
gnet “coupling/uncoupling” system which
allows the ventilation unit to be removed from its base during maintenance.
✓
Back-up touch button (E) at the side of the ventilation unit.
✓
Unique design winglet-type impeller, providing enhanced aerodynamic
properties, low noise and increased efficiency.
✓
Highly efficient reversible EC motor with integral thermal protection, mounted on
sealed for life high quality ball bearings. Designed for continuous reversible
running.
Содержание AF 90-CYC-ONEP-100
Страница 10: ...9 21...
Страница 12: ...11 21 5 0 Installation and figures...
Страница 13: ...12 21...
Страница 14: ...13 21...
Страница 15: ...14 21...
Страница 16: ...15 21...
Страница 17: ...16 21...
Страница 18: ...17 21...
Страница 19: ...18 21...
Страница 20: ...19 21 Notes...
Страница 21: ...20 21 Notes...