background image

 

1/21 

 

CONTENTS 

PLEASE KEEP THESE INSTRUCTIONS WITH THE PRODUCT. 

Please read this manual fully prior to installing the MVHR unit. 

 

 

1.0 

Introduction ........................................................................................................................ 2 

1.1 

Model Variations ................................................................................................................. 2 

1.2 

Product Guarantee .............................................................................................................. 3 

2.0 

Safety .................................................................................................................................. 3 

2.1 

Technical specifications ...................................................................................................... 4 

2.2 

Responsibility of the Installer.............................................................................................. 5 

2.3 

Responsibility of the Occupant ........................................................................................... 5 

3.0 

Specifications/ Dimensions ................................................................................................. 6 

3.2 

Detailed Specification ......................................................................................................... 6 

3.3 

ErP Directive - Regulations 1253/2014 - 1254/2014 .......................................................... 7 

4.0 

Operation ............................................................................................................................ 8 

4.1 

Remote functions ................................................................................................................ 8 

4.2 

Alerts and solutions .......................................................................................................... 10 

4.3 

Disposal and recycling ....................................................................................................... 10 

5.0 

Installation and figures...................................................................................................... 11 

Notes ............................................................................................................................................. 19 

Customer Support ......................................................................................................................... 21 

 

 

 

Содержание AF 90-CYC-ONEP-100

Страница 1: ...ation maintenance user manual Applicable to the following Aircycle ONE models PRODUCT CODE DESCRIPTION AF 90 CYC ONEP 100 aircycle ONE 100 AF 90 CYC ONEP 150 aircycle ONE 150 single room heat recovery...

Страница 2: ...2 0 Safety 3 2 1 Technical specifications 4 2 2 Responsibility of the Installer 5 2 3 Responsibility of the Occupant 5 3 0 Specifications Dimensions 6 3 2 Detailed Specification 6 3 3 ErP Directive R...

Страница 3: ...ling problems associated with condensation dampness such as mould growth It is recommended that two units are installed in pair when one unit is pulling the other is pushing Pair of units can be insta...

Страница 4: ...fully to ensure safe installation and operation of the unit The device should not be used for applications other than those specified in this manual After removing the product from its packaging verif...

Страница 5: ...sure adequate air return discharge into from the room in compliance with existing regulations in order to ensure proper device operation If the environment in which the product is installed also house...

Страница 6: ...he unit is double insulated no earth connection is required No need of condensation drainage system IPX4 degree of protection Power supply 220 240V 50Hz 2 2 Responsibility of the Installer Correct Ins...

Страница 7: ...unit status Simplified synchronisation of up to 10 units units get automatically synchronised when they are wired to each other Totally recyclable plastic components Double insulated no earth connect...

Страница 8: ...nput SPI W m3 h 0 139 0 80 n1 Control factor 0 65 0 65 n2 Control typology Local demand control o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 1 p1 Internal mixing rate N A p2...

Страница 9: ...ng functionalities can be activated deactivated When a setting is transferred to the unit a short acoustic signal is emitted and a green led flashes In case the remote controller gets lost or the batt...

Страница 10: ...9 21...

Страница 11: ...uct in question at suitable electronic and electro technical waste disposal collection centres or else send the product back to the retailer when purchasing a new equivalent type device Separate colle...

Страница 12: ...11 21 5 0 Installation and figures...

Страница 13: ...12 21...

Страница 14: ...13 21...

Страница 15: ...14 21...

Страница 16: ...15 21...

Страница 17: ...16 21...

Страница 18: ...17 21...

Страница 19: ...18 21...

Страница 20: ...19 21 Notes...

Страница 21: ...20 21 Notes...

Страница 22: ...happy to assist you Brookvent Brook House Dunmurry Industrial Estate Dunmurry Belfast Northern Ireland BT17 9HU T 44 0 28 9061 6505 It is important to retain this manual and make a copy available to...

Отзывы: