Installation and Operation Manual

X-TMF-SLA5800-Series-RevB-MFC-eng

Part Number: 541B187AAG

January, 2017

Brooks

®

 Digital MFC's & MFM's

LIMITED WARRANTY

Visit 

www.BrooksInstrument.com

 for the terms and conditions of our limited warranty.

BROOKS SERVICE AND SUPPORT

Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with
outstanding service and support to back it up. We operate first class repair facilities located around the world to provide
rapid response and support. Each location utilizes primary standard calibration equipment to ensure accuracy and reliability
for repairs and recalibration and is certified by our local Weights and Measures Authorities and traceable to the relevant
International Standards.

Visit www.BrooksInstrument.com to locate the service location nearest to you.

START-UP SERVICE AND IN-SITU CALIBRATION

Brooks Instrument can provide start-up service prior to operation when required.
For some process applications, where ISO-9001 Quality Certification is important, it is mandatory to verify and/or (re)calibrate
the products periodically. In many cases this service can be provided under in-situ conditions, and the results will be traceable
to the relevant international quality standards.

CUSTOMER SEMINARS AND TRAINING

Brooks Instrument can provide customer seminars and dedicated training to engineers, end users and maintenance persons.

Please contact your nearest sales representative for more details.

Due to Brooks Instrument's commitment to continuous improvement of our products, all specifications are subject to change without notice.

TRADEMARKS
Brooks is a trademark of Brooks Instrument, LLC
All other trademarks are the property of their respective owners.

Содержание SLA5850

Страница 1: ...nuary 2017 Brooks Digital MFC s MFM s Brooks SLA5800 Series Elastomer Sealed Digital Thermal Mass Flow Meters and Controllers Model SLA5850 with RS485 Communications Model SLA5850 with DeviceNet Communications Model SLA5850 with Profibus Communications Model SLA5851 with EtherCAT Communications ...

Страница 2: ...icable local and national codes Connect all products to the proper electrical and pressure sources Operation 1 Slowly initiate flow into the system Open process valves slowly to avoid flow surges 2 Check for leaks around the flow meter inlet and outlet connections If no leaks are present bring the system up to the operating pressure Please make sure that the process line pressure is removed prior ...

Страница 3: ...ll research and chemicals to medical devices analytical instrumentation semiconductor manufacturing and more The Brooks product you have just received is of the highest quality available offering superior performance reliability and value to the user It is designed with the ever changing process conditions accuracy requirements and hostile process environments in mind to provide you with a lifetim...

Страница 4: ...Installation and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 Brooks Digital MFC s MFM s THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 5: ... DeviceNet Profibus Foundation Fieldbus EtherCAT 2 10 Section 3 Operation 3 1 Overview 3 1 3 2 Theory of Operation for Flow Measurement 3 1 3 3 Features 3 3 3 4 Analog I O Mode of Operation 3 4 3 5 Communications Features 3 5 3 5 1 RS485 Communications Features Analog versions only 3 5 3 5 2 DeviceNet Communications Features 3 6 3 5 3 Profibus Communications Features 3 6 3 5 4 EtherCAT Communicati...

Страница 6: ...wnport RS485 1 12 1 10 Dimensions Model SLA5851 Thru Flow EtherCAT 1 13 1 11 Dimensions Model SLA5851 Thru Flow DeviceNet 1 13 1 12 Dimensions Model SLA5860 Thru Flow Profibus 1 14 1 13 Dimensions Model SLA5860 Thru Flow RS485 1 14 1 14 Dimensions Model SLA5861 Thru Flow RS485 1 15 1 15 Dimensions Model SLA5863 Thru Flow DeviceNet 1 15 1 16 Dimensions Model SLA5853 Thru Flow Profibus 1 16 1 17 Dim...

Страница 7: ...ended that this manual be read in its entirety before attempting to operate or repair these Brooks Digital products 1 3 Description The SLA5800 Series provides a highly configurable platform based on a simple modular architecture The SLA5800 Series feature set was carefully selected to enable drop in replacement and upgrade of many brands of mass flow controllers With the wide range of options and...

Страница 8: ...Brooks representative about your specific needs Advanced Thermal Flow Measurement Sensor Brooks sensor technology combines Excellent signal to noise performance for improved accuracy at low setpoints Superior long term stability through enhanced sensor manufacturing and burn in process Isothermal packaging to reduce sensitivity to external temperature changes Corrosion resistant sensor flow path A...

Страница 9: ...nearity Linearity Linearity Linearity Included in accuracy Response Time Response Time Response Time Response Time Response Time Settling Time within Settling Time within Settling Time within Settling Time within Settling Time within 1 second 3 seconds 2 F S for 0 100 command step 2 F S for 0 100 command step 2 F S for 0 100 command step 2 F S for 0 100 command step 2 F S for 0 100 command step Ze...

Страница 10: ... Input Impedence Input Impedence Input Impedence 100 Ohms N A N A Flow Output Voltage Specifications Flow Output Voltage Specifications Flow Output Voltage Specifications Flow Output Voltage Specifications Flow Output Voltage Specifications Nominal Range Nominal Range Nominal Range Nominal Range Nominal Range 0 5 Vdc 1 5 Vdc or 0 10 Vdc N A N A Full Range Full Range Full Range Full Range Full Rang...

Страница 11: ...in an area of not more than pollution degree 2 as defined in IEC 60664 1 Reference Conditions Due to effects of pressure and temperature on the compressibility of gases specific reference conditions must be used when reporting volumetric flow rates in mass flow terms For example the unit of measure SCCM standard cubic centimeters per minute refers to a volumetric gas flow at a standard reference c...

Страница 12: ...oltage signals to Pin 11 8 on Firmware Version 1 18 newer Selectable Soft Start Processes requiring injection of gases can be adversely affected by excessive initial gas flow This abrupt injection of gas can result in process damage from explosion or initial pressure impact These problems are virtually eliminated with the soft start feature Figure 1 1 General Wiring PC based Support Tools Brooks I...

Страница 13: ...ry 2017 Figure 1 3 Linear Ramp up and or Ramp down from 200 Per Second Down to 0 5 Per Second Setpoint Change Figure 1 2 Response Performance of Brooks Digital MFC Linear ramp up or ramp up down Figure 1 3 set by user via software tools or digital commands Linear ramp up ramp down is adjustable at 200 per second down to 0 5 per second setpoint change ...

Страница 14: ...sonal computers are not equipped with RS485 ports as standard An RS232 USB to RS485 converter or RS485 interface board is therefore required to connect an RS485 network to a standard personal computer The RS485 bus a daisy chain network meaning that the wires are connected at the units as in Figure 1 1 Figure 1 4 SLA5800 Series RS485 15 Pin Analog Connector and Pinouts Function PIN Setpoint Common...

Страница 15: ...The communication electronics allows for automatic baud rate detection ranging from 9600 baud to 12 Mbaud thus making the need for any hardware baud rate selection methods not required For selecting the device address which must be unique on the network two rotary switches are provided This allows a user to easily select any address number ranging from 0 to 126 This can provide fast device replace...

Страница 16: ...ing standard body for DeviceNet DeviceNetis similar to the RS485 standard in that it is a multi drop connection that allows a maximum of 64 devices to be connected on the same network Baud rate selections for DeviceNetproducts are 125K 250K and 500K and can be selected via a rate switch mounted on the device The DeviceNetcommunication link also provides access to many of the Brooks SLAMf Digital S...

Страница 17: ... maintainability EtherCAT is an Ethernet based communication system and is known for its high cycle time and cost efficient cabling and master application solutions The available physical interfaces on the EtherCAT device are listed below 5 pin M8 threaded male connector for power andAnalog l O indicated by pwr ln and Out ports with RJ 45 connectors 2 5mm female jack for RS485 diagnostic port indi...

Страница 18: ...00 Series RevB MFC eng Part Number 541B187AAG January 2017 Figure1 8 Dimensions Model SLA5850 Thru Flow RS485 Figure 1 9 Dimensions Model SLA5850 Downport RS485 Note Aux Input is used for Remote Transducer Pressure Controllers only Note Aux Input is used for Remote Transducer Pressure Controllers only ...

Страница 19: ...ies RevB MFC eng Part Number 541B187AAG January 2017 Figure 1 10 Dimensions Model SLA5851 Thru Flow EtherCAT Figure 1 11 Dimensions Model SLA5851 Thru Flow DeviceNet Note Aux Input is used for Remote Transducer Pressure Controllers only Note Aux Input is used for Remote Transducer Pressure Controllers only ...

Страница 20: ...and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 Figure 1 12 Dimensions Model SLA5860 Thru Flow Profibus Figure 1 13 Dimensions Model SLA5860 Thru Flow RS485 Note Aux Input is used for Remote Transducer Pressure Controllers only ...

Страница 21: ...eries RevB MFC eng Part Number 541B187AAG January 2017 Figure 1 14 Dimensions Model SLA5861 Thru Flow RS485 Figure 1 15 Dimensions Model SLA5863 Thru Flow DeviceNet Note Aux Input is used for Remote Transducer Pressure Controllers only Note Aux Input is used for Remote Transducer Pressure Controllers only ...

Страница 22: ...ries RevB MFC eng Part Number 541B187AAG January 2017 Figure 1 16 Dimensions Model SLA5853 Thru Flow Profibus Figure 1 17 Dimensions Model SLA5853 Thru Flow EtherCAT Note Aux Input is used for Remote Transducer Pressure Controllers only Note Aux Input is used for Remote Transducer Pressure Controllers only ...

Страница 23: ...with the packing materials Inspect for damaged or missing parts 2 3 Recommended Storage Practice If intermediate or long term storage of equipment is required it is recommended that the equipment be stored in accordance with the following a Within the original shipping container b Stored in a sheltered area preferably a warm dry heated warehouse c 32 C 90 F maximum 45 F 7 C minimum d Relative humi...

Страница 24: ... Upon removal from storage a visual inspection should be conducted to verify the condition of the equipment is as received If the equipment has been in storage in conditions in excess of those recommended See Section 2 3 the device should be subjected to a pneumatic pressure test in accordance with applicable vessel codes 2 7 Gas Connections Prior to installation ensure all piping is clean and fre...

Страница 25: ...equires servicing d The Brooks Digital MFC or MFM can be installed in any position However mounting in orientations other than the original factory calibration see calibration data sheet supplied with the instrument can result in a 0 2 maximum full scale shift after re zeroing e When installing a mass flow controller or meter with full scale flow rates of 10 lpm or greater be aware that sharp abru...

Страница 26: ...e which in turn controls the flow through the device The main valve is a pressure operated valve that utilizes a bellows spring and diaphragm to control flow This bellows and diaphragm assembly can be susceptible to damage by pressure spikes or surges For this reason it is recommended that process line startups are handled with care The bellows spring is offered in two levels A low force for low d...

Страница 27: ...mbient temperature the bypass ratio accuracy will be affected When a hot or cold process fluid is being measured ensure that the piping system is designed to allow the gas temperature to equalize with the flow controller ambient temperature For more information please contact the Brooks Technical Service group 2 10 Electrical Interface The setpoint signal is supplied as a 0 1 to 5 Vdc 0 to 10 Vdc ...

Страница 28: ...l MFC s MFM s Section 2 Installation Installation and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 Figure 2 1 RS485 D Connector Shielded Cable Hookup Diagram Voltage I O Version ...

Страница 29: ... Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 Figure 2 2 Recommended I O Wiring Configuration for Current Signals Non Isolated Power Supply Figure 2 3 Recommended I O Wiring Configuration for Current Signals Isolated Power Supply ...

Страница 30: ...ter system Personal computers are not equipped with RS485 ports as standard An RS232 to RS485 converter or RS485 interface board is therefore required to connect an RS485 to a standard PC Figure 2 4 is an interconnection diagram showing two TMFs linked to a PC via RS485 and RS485 to RS232 converter The RS485 bus a daisy chain network meaning that the wires are connected at the units as in Figure 2...

Страница 31: ...0 000 mA 40 μA 0 20 mA output 4 000 mA 40 μA 4 20 mA output f Turn on the gas supply A positive flow signal may be present due to slight valve leak thru MFC only g Supply a setpoint signal between 0 to 5 Vdc 0 5 Vdc setpoint or 0 to 10 Vdc 0 10 Vdc setpoint 1 to 5 Vdc 1 5 Vdc setpoint 0 to 20 mA 0 20 mA setpoint 4 to 20 mA 4 20 mA setpoint h Check the analog output signal The output signal should ...

Страница 32: ...as type When checking with a surrogate gas ensure that there is enough pressure to the MFC in order to flow the correct amount of the surrogate gas Example Checking an MFC calibrated for 100 ccm SF6 sulfur hexafluoride The sensor factor N2 nitrogen is 0 27 therefore the equivalent N2 needed is 100 0 27 370 4 ccm This may require a pressure increase to make this flow rate 2 13 Bus Network DeviceNet...

Страница 33: ...the same linear pressure difference versus flow relationship The ratio of sensor flow to the flow through the restrictor remains constant over the range of the MFC MFM A B constant The full scale flow rate of the MFC MFM is established by selecting a restrictor with the correct pressure differential for the desired flow The flow sensor is a very narrow thin walled stainless steel tube Onto this tu...

Страница 34: ...igital MFC s MFM s Section 3 Operation Installation and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 Figure 3 1 Flow Sensor Operational Diagram VCRTM End Connections Shown ...

Страница 35: ...ibration data Each set includes a calibration curve PID controller settings valve performance data and information about the calibration conditions The Brooks Digital equipment can contain calibrations for different gases or for the same gas at multiple conditions pressures full scale flow rates The DeviceNet Profibus EtherCAT and RS485 Instruction Manuals describe further details on specific comm...

Страница 36: ...p apply gas pressure then proceed by following the instructions in the following sections Analog I O Setpoint MFC Only This input allows the user to establish the MFC setpoint Several input types are available as follows Analog I O Flow Signal This output is used to indicate the flow signal A negative flow signal indicates reverse flow through the device but is NOT calibrated Several flow signal t...

Страница 37: ...ero flow reading This will result in calibration inaccuracy during normal operation Once zero differential pressure is established and verified press the recessed momentary push button zero button located on the side of the device See Figure 3 2 to start the zero function 3 5 Communications Features 3 5 1 RS485 Communications Features Analog versions only Digital communication designed to emulate ...

Страница 38: ...ction ranging from 9600 baud to 12 Mbaud thus making the need for any hardware baud rate selection methods not required For selecting the device address which must be unique on the network two rotary switches are provided This allows a user to easily select any address number ranging from 0 to 126 This can provide fast device replacement without complex network configurations The Profibus DP commu...

Страница 39: ...setpoint actuator override etc Read Diagnostics information warning alarm status Check Device configuration Calibration due status Hardware Software versions etc Various companies provide EtherCAT master applications e g TwinCAT from Beckoff or offer EtherCAT master stacks to develop a master application e g Acontis A P C can be used to run most EtherCAT master applications but needs dedicated Eth...

Страница 40: ...the specified conditions When the alarm is set to latching This means that the alarm will be indicated when the monitored value first exceeds the specified conditions and will be indicated until the user clears the alarm If the user clears the alarm while the monitored value still exceeds the specified conditions then the alarm will be re latched and continue to be indicated Contact Enable If the ...

Страница 41: ...larm The Setpoint Deviation Alarm monitors the difference between Setpoint and Flow and sets the alarm when the difference exceeds the specified limits for more than the specified delay period The user specifies a minimum and maximum limit in percent of Setpoint This alarm is disabled if the valve override is active Temperature Out of Limits The Temperature Out of Limits alarm will occur when the ...

Страница 42: ...tion configuration sets can be saved in order to have a unit pre configured for multiple gas calibration different pressure conditions multiple scalings of the same gas Calibration and configuration data sets may be adjusted by an advanced user via the Diagnostics Port using a special software application available from Brooks Reference the Brooks Expert Support Tool User Manual BEST for more info...

Страница 43: ... the Low Flow Output Cutoff parameter the Flow Output will be set to zero 3 8 4 Adaptive Control Adaptive Valve Control is a means of dynamically adjusting valve offset and span in response to changing process conditions Options for Adaptive Control are On Off Adjust Offset Only Adjust Offset and Span 3 8 5 Flow Totalizer A Flow Totalizer will be provided and maintained in Non Volatile Memory The ...

Страница 44: ...3 12 Brooks Digital MFC s MFM s Section 3 Operation Installation and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 45: ...Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG June 2016 4 1 Maintenance and Troubleshooting No routine maintenance is required on the Brooks Digital MFC s and MFM s If an in line filter is used the filtering elements should be periodically replaced or cleaned ...

Страница 46: ...s maximum rate also the valve is likely to drive to max opening 100 4 Flow signal matched setpoint but actual flow is not correct Clogged restrictor If the MFC s restrictor becomes clogged a much larger flow stream will pass through the sensor rather than going straight through the restrictor The symptom of this condition is a substantially reduced actual flow with a flow signal which matches the ...

Страница 47: ...dress of the device on the network The possible range of addresses is 00 to 63 The out of box MAC ID setting is 63 The third rotary switch is labeled RATE This switch sets the baud rate of the MFC for communicating over the DeviceNet network The out of box default setting is 125K baud For more complete details on these switches reference the Brooks DeviceNet Supplement Instruction Manual Q What is...

Страница 48: ...e MFC MFM related problems in the gas distribution system and answers commonly asked questions Remove the sensor connector from the PC Board for this procedure OHMMETER CONNECTION RESULT IF ELECTRICALLY FUNCTIONAL Open circuit on ohmmeter If either heater 1 or Pin 1 or 4 to meter body sensor common 4 are shorted an ohmmeter reading will be obtained Pin 4 to Pin 2 Nominal 1100 ohms reading dependin...

Страница 49: ... Connect the instrument to a source of the same gas used for it s original calibration Regulate the Setpoint to 100 flow and adjust the inlet and outlet pressures to calibration conditions Verify that the output signal reaches its full scale value and stabilizes at that value Vary the command voltage over the 1 to 100 range and verify that the output signal follows the Setpoint If possible connect...

Страница 50: ... tube can then be flushed with a solvent that leaves no residue This can be accomplished conveniently using a hypodermic needle filled with solvent NOTE Do not soak the sensor assembly in a cleaning solvent If solvent seeps into the sensor assembly it will likely damage or significantly alter the sensor s operating characteristics 4 1 4 Calibration Procedure The calibration of Brooks Digital Serie...

Страница 51: ...utput signal follows Setpoint Control valve leaks or is stuck Clean the control valve or return the device at higher Setpoints but will not open to the factory Section 4 1 2 go below 2 Output signal follows Setpoint Insufficient inlet pressure or Adjust pressures inspect in line filters and at lower Setpoints but does pressure drop clean replace as necessary not reach full scale Partially clogged ...

Страница 52: ... Brooks Digital MFC s MFM s Section 4 Maintenance Troubleshooting Installation and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG June 2016 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 53: ...ɢ ɢ ɜɯɨɞɧɢ ɤɥɚɩɚɧɢ ɨɛɨɪɭɞɜɚɧɟɬɨ ɬɪɹɛɜɚ ɧɚɩɴɥɧɨ ɞɚ ɫɟ ɢɡɩɪɚɡɧɢ ɇɟɢɡɩɴɥɧɟɧɢɟɬɨ ɧɚ ɬɨɜɚ ɦɨɠɟ ɞɚ ɩɪɢɱɢɧɢ ɬɨɩɥɢɧɧɨ ɪɚɡɲɢɪɟɧɢɟ ɧɚ ɬɟɱɧɨɫɬɬɚ ɤɨɟɬɨ ɦɨɠɟ ɞɨ ɫɩɭɤɚ ɨɛɨɪɭɞɜɚɧɟɬɨ ɢ ɞɚ ɞɨɜɟɞɟ ɞɨ ɬɟɥɟɫɧɢ ɩɨɜɪɟɞɢ ȿɜɪɨɩɟɣɫɤɚ ɞɢɪɟɤɬɢɜɚ ɡɚ ɭɪɟɞɢ ɩɨɞ ɧɚɥɹɝɚɧɟ PED ȼɫɢɱɤɢ ɫɴɨɪɴɠɟɧɢɹ ɩɨɞ ɧɚɥɹɝɚɧɟ ɫ ɜɴɬɪɟɲɧɨ ɧɚɥɹɝɚɧɟ ɧɚɞ 0 5 bar g ɢ ɫ ɪɚɡɦɟɪ ɩɨ ɝɨɥɹɦ ɨɬ 25 mm ɢɥɢ 1 inch ɩɨɩɚɞɚɬ ɩɨɞ ɞɟɣɫɬɜɢɟɬɨ ɧɚ ɟɜɪɨɩɟɣɫɤɚɬɚ ɞɢɪɟɤɬɢɜɚ ɡ...

Страница 54: ...í kompletnČ vyprázdnit Pokud tak neuþiníte mĤže z dĤvodu teplotní roztažnosti zbytkĤ média v zaĜízení dojít k jeho poškození nebo k ohrožení zdraví osob Evropská smČrnice pro tlakové zaĜízení PED Na veškerá tlaková zaĜízení s vnitĜním tlakem vyšším než 0 5 baru g a velikosti vČtší než 25 mm nebo 1 palec se vztahuje platnost smČrnice o tlakovém zaĜízení PED Kapitola Technické údaje v této pĜíruþce ...

Страница 55: ...entilen ikke bliver lukket på samme tid i forbindelse med aftapning Såfremt dette ikke overholdes er der risiko for at væsken på grund af varmeudvikling ekspanderer og dette kan forårsage skade på udstyr og personer Det Europæiske direktiv for trykudstyr PED På alt udstyr hvis indgangstryk er større end 0 5bar g og større end 25 mm eller en tomme gælder det europæiske direktiv for trykapparater Ma...

Страница 56: ...n afgetapt Als dat wordt nagelaten kan dit leiden tot thermische expansie van de vloeistof waardoor het apparaat kan barsten en lichamelijk letsel kan veroorzaken PED Pressure Equipment Directive Alle drukapparatuur met een interne druk van meer dan 0 5 barg en een diameter van meer dan 25 mm valt onder de PED richtlijn In het hoofdstuk Specificaties van deze handleiding staan aanwijzingen die ver...

Страница 57: ...Vastasel korral võib vedelik soojuse mõjul paisuda niivõrd et seade puruneb See võib põhjustada raskeid kehavigastusi Euroopa surveseadmete direktiiv PED Euroopa surveseadmete direktiiv kohaldub kõikidele surveseadmetele mille sisesurve on üle 0 5 baari g ja läbimõõt üle 25 mm või 1 tolli x Selle kasutusjuhendi spetsifikatsiooniosa sisaldab surveseadmete direktiiviga seonduvaid juhiseid x Kasutusj...

Страница 58: ...aiminlyönti aiheuttaa nesteen lämpölaajenemista joka saattaa johtaa laitteen rikkoutumiseen ja henkilövahingon vaaraan Eurooppalainen painelaitedirektiivi PED Painelaitteet joiden paine on suurempi kuin 0 5 bar g ja joiden koko on suurempi kuin 25 mm tai 1 tuuma kuuluvat eurooppalaiseen painelaitedirektiiviin PED x PED direktiiviä koskevat määräykset löytyvät käyttöoppaan Tekniset tiedot luvusta x...

Страница 59: ... cela n est pas fait une éventuelle dilatation thermique du fluide peut casser l appareil et provoquer des blessures Directive européenne équipements sous pression PED Tous les équipements sous pression dont la pression interne est supérieure à 0 5 bar pression relative et dont la taille dépasse 25 mm ou un pouce entrent dans le cadre de la directive PED La section Spécifications de ce manuel cont...

Страница 60: ...ntilen komplett entleert werden anderenfalls kann es zu einer thermischen Ausdehnung der Flüssigkeit und damit zum Bruch des Gerätes kommen Personenschäden können die Folge sein Europäische Druckgeräterichtlinie PED Alle Druckgeräte mit einem internen Druck von mehr als 0 5 bar g und einer Größe von mehr als 1in 1 in 25 4 mm unterliegen der Druckgeräterichtlinie Das Kapitel zu den technischen Date...

Страница 61: ...ȠȪȞ İȞIJİȜȫȢ Ǿ ȝȘ ıȣȝȝȩȡijȦıȘ ȝʌȠȡİȓ ȞĮ ʌȡȠțĮȜȑıİȚ șİȡȝȚțȒ įȚĮıIJȠȜȒ IJȠȣ ȣȖȡȠȪ ʌȠȣ ʌİȡȚȑȤȠȣȞ ȝİ ĮʌȠIJȑȜİıȝĮ ȞĮ ȡĮȖȓıİȚ Ș ıȣıțİȣȒ țĮȚ ȞĮ ʌȡȠțȜȘșȠȪȞ ʌȡȠıȦʌȚțȠȓ IJȡĮȣȝĮIJȚıȝȠȓ ǼȣȡȦʌĮȧțȒ ȅįȘȖȓĮ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ȣʌȩ ʌȓİıȘ PED ȀȐșİ İȟȠʌȜȚıȝȩȢ ȣʌȩ ʌȓİıȘ ȝİ İıȦIJİȡȚțȒ ʌȓİıȘ ȐȞȦ IJȠȣ 0 5 bar g țĮȚ ȝİȖȑșȠȣȢ ȝİȖĮȜȪIJİȡȠȣ IJȦȞ 25 mm Ȓ IJȘȢ 1 ȓȞIJıĮȢ İȝʌȓʌIJİȚ ıIJȚȢ įȚĮIJȐȟİȚȢ IJȘȢ İȣȡȦʌĮȧțȒȢ ȅįȘȖȓĮȢ ȖȚĮ IJȠȞ İȟȠʌȜȚıȝȩ ȣʌȩ ʌȓ...

Страница 62: ...ti ki és belépĘ szelepeket a berendezést teljesen le kell üríteni Ennek elmulasztása a folyadék hĘtágulását okozhatja ami károsíthatja a berendezést és személyi sérüléshez vezethet Nyomástartó berendezésekre vonatkozó európai irányelv PED Minden 0 5 bar nál g magasabb belsĘ nyomású és 25 mm nél vagy 1 hüvelyknél nagyobb nyomástartó berendezés a nyomástartó berendezésekre vonatkozó európai irányelv...

Страница 63: ...si deve svuotare completamente l apparecchiatura L inosservanza può causare la dilatazione termica del liquido che può danneggiare l apparecchiatura e provocare lesioni alle persone Direttiva europea relativa alle apparecchiature a pressione PED Ogni apparecchiatura a pressione con pressione interna maggiore di 0 5 bar g e più grande di 25 mm o di 1 pollice ricade nell ambito della Direttiva Europ...

Страница 64: ...as ierƯþu tuvumƗ esošos ieplnjdes un izplnjdes vƗrstus kƗda iemesla dƝƺ ir jƗaizver no ierƯcƝm ir jƗizlaiž viss šƷidrums PretƝjƗ gadƯjumƗ šƷidrums var termiski izplesties pƗrraut ierƯci un radƯt traumas Eiropas spiedieniekƗrtu direktƯva PED Uz visƗm spiedieniekƗrtƗm kuru iekšƝjais spriegums pƗrsniedz 0 5 bar g un ir lielƗkas par 25 mm jeb 1 collu attiecas Eiropas spiedieniekƗrtu direktƯva PED x ŠƯs ...

Страница 65: ...vus iš Ƴrenginio reikia išleisti visą skystƳ To nepadarius galimas šiluminis skysþio plơtimasis galintis sugadinti ƳrenginƳ ir sužeisti žmonơs Europos slơginơs Ƴrangos direktyva PED Visa slơginơ Ƴranga kurios vidinis slơgis didesnis nei 0 5 bar g o dydis didesnis nei 25 mm arba 1 col yra reglamentuojama Slơginơs Ƴrangos direktyvos PED x Šios instrukcijos dalyje Techniniai duomenys pateikiami nurod...

Страница 66: ...eczy jeĪeli znajdujące siĊ na nich zawory wejĞciowe i wyjĞciowe mają byü z jakiegoĞ powodu zamkniĊte to urządzenie musi zostaü caákowicie opróĪnione z ciekáego medium Niedopeánienie tego zalecenia moĪe doprowadziü do termicznego zwiĊkszenia objĊtoĞci cieczy co z kolei moĪe spowodowaü uszkodzenie urządzenia i obraĪenia personelu Europejska dyrektywa dotycząca urządzeĔ ciĞnieniowych PED Wszystkie ur...

Страница 67: ...rio fechar as válvulas a montante e jusante do equipamento tenha em atenção que o mesmo deverá ser previamente esvaziado do fluído que o atravessa Esta obrigação surge do facto de existir a possibilidade de ocorrer dilatação térmica do líquido no interior do aparelho podendo provocar danos pessoais ou materiais graves Directiva Europeia para equipamentos sob pressão PED Todos os equipamentos sujei...

Страница 68: ...închiderea valvelor de intrare úi ieúire limitrofe instalaĠiei instalaĠia trebuie complet golită Neglijarea acestui lucru poate avea ca efect dilatarea termică a fluidului care poate defecta instalaĠia úi poate produce răniri de persoane Directiva europeană pentru instalaĠiile sub presiune PED Toate instalaĠiile úi sistemele presurizate ce se află sub presiuni interne ce depăúesc 0 5 mbar g úi au ...

Страница 69: ...tné uzavrieĢ vstupné a výstupné ventily zariadenie je potrebné úplne vyprázdniĢ Zanedbanie vypúšĢania má za následok poškodenie zariadenia s možnosĢou zranenia obsluhy z dôvodu tepelnej rozĢažnosti náplne Európska smernica vzĢahujúca sa na tlakové zariadenia PED x Všetky zariadenia s vyšším vnútorným pretlakom ako 0 5 bar g a väþšieho rozmeru ako 25 mm alebo 1 anglický palec podliehajú pod Európsk...

Страница 70: ...olnoma izprazniti ýe tega ne naredite lahko pride do toplotnega raztezanja tekoþine zaradi katerega se lahko naprava prelomi in povrzoþi telesne poškodbe Evropska direktiva o tlaþni opreni PED Vsa tlaþna oprema z notranjim tlakom ki je veþji od 0 5 bara g in velikostjo ki je veþja od od 25 mm ali 1 palca spada v direktivo o tlaþni opremi PED x V poglavju Tehniþni podatki v tem priroþniku najdete n...

Страница 71: ...do del equipo dichas instalaciones deberán ser completamente vaciadas La omisión de esto último puede provocar la dilatación térmica del líquido lo que puede dañar al equipo y conducir a daños personales Directriz Europea de los Equipos de Presión PED Todos los equipos de presión con una presión interna que supere a 0 5 bar g con tamaño mayor a 25 mm o 1 pulgada entran el ámbito de la Directriz Eu...

Страница 72: ...trustningen och orsaka personliga skador European Pressure Equipment Directive PED Rådets Direktiv 99 36 EG av den 29 april 1999 1 om transportabla tryckbärande anordningar Alla utrustning för tryck med ett tryck över 0 5 Bar g bar och större demensioner än 25 mm eller 1 inch faller under Tryck direktiv 99 36 EG av den 29 april 1999 1 om transportabla tryckbärande anordningar PED x Den här Instruk...

Страница 73: ...Installation and Operation Manual X TMF SLA5800 Series RevB MFC eng Part Number 541B187AAG January 2017 Brooks Digital MFC s MFM s THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 74: ...Visit www BrooksInstrument com to locate the service location nearest to you START UP SERVICE AND IN SITU CALIBRATION Brooks Instrument can provide start up service prior to operation when required For some process applications where ISO 9001 Quality Certification is important it is mandatory to verify and or re calibrate the products periodically In many cases this service can be provided under i...

Отзывы: