background image

1-5

Models 1350E and 1355E

Section 1 Introduction

Installation and Operation Manual

X-VA-1350E-eng
Part Number: 541B082AAG
February, 2011

Table 1-5 Capacities for Sho-Rate Model 1355E Rib Guided Tubes, Spherical Floats

NOTE: ALL AI R FLOWS ARE AT 14.7 PSIA AND 70 DEGREES F.

*  FLOW  RATES SHOWN ARE MAXIMUM  CAPACITIES
     DIRECT READ SCALES  MAY END  AT SLIGHTLY DIFFERENT MAXIMUM FLOWS.

CAPACITIES (RIB GUIDE TUBES, SPHERICAL FLOATS) - FOR USE WITH 1355 SERIES ONLY

MAXIMUM FLOW RATE *

MODEL CODE - SCALE ON TUBE

METER

WATER

SIZE

TUBE NO.

FLOAT MATERIAL

(CC/MIN.)

AIR

0-150 MM

 10-100%

0-100 LINEAR

GLASS

0.537

50 SCC/M

CA6

CA1

SAPPHIRE

1.05

77 SCC/M

CA8

CA3

R-2-15-AAA

STN. STL.

2.49

148 SCC/M

CA7

CA2

CARBOLOY

4.9

251 SCC/M

CA9

CA4

TANTALUM

5.47

274 SCC/M

CB1

CA5

GLASS

1.11

88 SCC/M

BA6

BA1

SAPPHIRE

2.15

136 SCC/M

BA8

BA3

R-2-15-AA

STN. STL.

4.93

258 SCC/M

BA7

BA2

CARBOLOY

9.33

439 SCC/M

BA9

BA4

TANTALUM

10.4

478 SCC/M

BB1

BA5

GLASS

5.75

380 SCC/M

FA6

FA1

SAPPHIRE

10.5

518 SCC/M

FA8

FA3

2

R-2-15-D

STN. STL.

20.6

832 SCC/M

FA7

FA2

CARBOLOY

33.2

1240 SCC/M

FA9

FA4

TANTALUM

35.9

1320 SCC/M

FB1

LIQ.

GAS

FA5

GLASS

16.6

.83 SLPM

AA6

AB7

AC3

AA1

SAPPHIRE

26.3

1.1 SLPM

AA8

AB9

AC4

AA3

R-2-15-A

STN. STL.

46.2

1.69 SLPM

AA7

AB8

AC6

AA2

CARBOLOY

70.8

2.44 SLPM

AA9

AC1

AC5

AA4

TANTALUM

75.9

2.6 SLPM

AB1

AC2

AC7

AA5

GLASS

52.8

2.37 SLPM

DA6

DB2

DA1

SAPPHIRE

79.7

3.08 SLPM

DA8

DB4

DA3

R-2-15-B

STN. STL.

133

4.7 SLPM

DA7

DB3

DA2

CARBOLOY

199

6.7 SLPM

DA9

DB5

DA4

TANTALUM

212

7.1 SLPM

DB1

DB6

DA5

GLASS

84.6

3.9 SLPM

EA6

EB2

EA1

SAPPHIRE

129

5.1 SLPM

EA8

EB4

EA3

R-2-15-C

STN. STL.

218

7.6 SLPM

EA7

EB3

EA2

CARBOLOY

326

10.6 SLPM

EA9

EB5

EA4

TANTALUM

349

11.3 SLPM

EB1

EB6

EA5

GLASS

200

8.7 SLPM

GA6

GB2

GA1

SAPPHIRE

297

11.2 SLPM

GA8

GB4

GA3

R-6-15-A

STN. STL.

493

16.6 SLPM

GA7

GB3

GA2

CARBOLOY

726

23.2 SLPM

GA9

GB5

GA4

6

TANTALUM

772

24.6 SLPM

GB1

GB6

GA5

GLASS

573

23.9 SLPM

HA6

HB2

HA1

SAPPHIRE

851

30.2 SLPM

HA8

HB4

HA3

R-6-15-B

STN. STL.

1350

43.8 SLPM

HA7

HB3

HA2

CARBOLOY

1950

61.2 SLPM

HA9

HB5

HA4

TANTALUM

2060

64.7 SLPM

HB1

HB6

HA5

Содержание Sho-Rate 1350E

Страница 1: ...and Sho RateTM 150 Model 1355E Sizes 2 6 Model 1350E Sho Rate 50 With optional needle valve Model 1355E Sho Rate 150 With optional needle valve Model 1350E Sho Rate 50 With optional Integral flow controller Model 1355E Sho Rate 150 With optional Integral flow controller Model 1350E Sho Rate 50 no valve Model 1355E Sho Rate 150 no valve ...

Страница 2: ... flow into the system Open process valves slowly to avoid flow surges 2 Check for leaks around the flow meter inlet and outlet connections If no leaks are present bring the system up to the operating pressure Please make sure that the process line pressure is removed prior to service When replacement parts are required ensure that qualified people use replacement parts specified by Brooks Instrume...

Страница 3: ... and chemicals to medical devices analytical instrumentation semiconductor manufacturing and more The Brooks product you have just received is of the highest quality available offering superior performance reliability and value to the user It is designed with the ever changing process conditions accuracy requirements and hostile process environments in mind to provide you with a lifetime of depend...

Страница 4: ...Models 1350E and 1355E Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 5: ...bly Cleaning 4 1 Section 5 Parts List Paragraph Page Number Number 5 1 General 5 1 Figures Figure Page Number Number 2 1 Typical Flowmeter Installation 2 3 2 2 Dimensions Sho Rate1350E 2 4 2 3 Dimensions Sho Rate1350E and 1355E with Integral Controller 2 5 2 4 Dimensions Sho Rate1355E 2 6 5 1 Parts Drawing Sho Rate Models 1350E and 1355E 5 2 Tables Table Page Number Number 1 1 Capacities for Sho R...

Страница 6: ...ii Models 1350E and 1355E Contents Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 7: ... installation of the tube and float while the meter remains in the process piping 1 2 Specifications Capacities 1350 Series Refer to Tables 1 1 or 1 2 or 1 3 and 1 4 1355 Series Refer to Tables 1 3 and 1 4 or 1 5 Accuracy 1350 Series Standard Accuracy of 10 of full scale 1355 Series Standard 5 of full scale Repeatability 0 5 full scale Pressure Equipment Directive 97 23 EC Note Equipment falls und...

Страница 8: ...arboloy tantalum Structural Members End fittings Chrome plated brass black anodized aluminum 316 stainless steel Side Plates Standard Black anodized aluminum Optional 316 stainless steel Window Clear polycarbonate Back Window Milk white polycarbonate Float Stops Standard Teflon Optional 316 Stainless Steel Tube Packing Standard Buna N Brass and aluminum meters Viton A fluoroelastomers 316 stainles...

Страница 9: ...C5 R 6 65 A STN STL 5 50 ND1 20 0 ND3 26 0 NC9 650 ND2 CARBOLOY 8 50 NB2 32 0 NB3 36 0 NB5 950 NB6 TANTALUM 9 0 ND6 34 0 ND5 38 0 ND7 1000 ND4 6 GLASS 8 0 PB9 30 0 PB8 44 0 PC1 1100 PB7 SAPPHIRE 12 0 PC5 44 0 PC3 60 0 PC4 1500 PC2 R 6 65 B STN STL 19 0 PD1 70 0 PC9 85 0 PC8 2200 PC6 CARBOLOY 28 0 PB3 100 PB2 130 PB6 3400 PB4 TANTALUM 30 0 PD7 110 PD6 140 PD5 3600 PD4 FLOW RATES GIVEN ARE MAXIMUM V...

Страница 10: ...omplete instruction manual go to our website BrooksInstrument com select Documentation Precision Valves Flow Controllers select FC8800 or FC8900 CODE MODEL 1350 TUBE MODEL 1355 TUBE A 1 65 R 2 15 A B 2 65A R 2 15 AA C 2 65B D R 2 15 AAA D 2 65C R 2 15 B E 3 65 R 2 15 C F 4 65 R 2 15 D G 5 65 R 6 15 A H 6 65 R 6 15 B J R 2 65 A K R 2 65 B L R 2 65 C M R 2 65 D N R 6 65 A P R 6 65 B Y NO TUBE NO TUB...

Страница 11: ... GLASS 5 75 380 SCC M FA6 FA1 SAPPHIRE 10 5 518 SCC M FA8 FA3 2 R 2 15 D STN STL 20 6 832 SCC M FA7 FA2 CARBOLOY 33 2 1240 SCC M FA9 FA4 TANTALUM 35 9 1320 SCC M FB1 LIQ GAS FA5 GLASS 16 6 83 SLPM AA6 AB7 AC3 AA1 SAPPHIRE 26 3 1 1 SLPM AA8 AB9 AC4 AA3 R 2 15 A STN STL 46 2 1 69 SLPM AA7 AB8 AC6 AA2 CARBOLOY 70 8 2 44 SLPM AA9 AC1 AC5 AA4 TANTALUM 75 9 2 6 SLPM AB1 AC2 AC7 AA5 GLASS 52 8 2 37 SLPM ...

Страница 12: ...1 6 Models 1350E and 1355E Section 1 Introduction Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 13: ... LLC Hatfield PA 19440 should be contacted to obtain a return shipment form Brooks Instrument 407 W Vine Street P O Box 903 Hatfield PA 19440 USA Toll Free 888 554 FLOW 3569 Tel 215 362 3700 Fax 215 362 3745 E mail BrooksAm BrooksInstrument com www BrooksInstrument com Brooks Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands Tokyo 136 0073 Japan P O Box 428 T...

Страница 14: ... 3 5633 7100 6710 BK Ede Netherlands Fax 81 0 3 5633 7101 Tel 31 0 318 549 300 Email BrooksAs BrooksInstrument com Fax 31 0 318 549 309 E mail BrooksEu BrooksInstrument com 2 4 Recommended Storage Practice If intermediate or long term storage is required for equipment as supplied by Brooks Instrument it is recommended that said equipment be stored in accordance with the following a Within the orig...

Страница 15: ...B A E FLOWMETER C D FLOWMETER It is recommended that a final leak test of the system plumbing and meter be performed before subjecting it to process fluid See Section 4 Paragraph 4 2 e 2 5 Installation See Figures 2 1 2 2 2 3 2 4 and 2 5 The flowmeter should be mounted within 6 of true vertical The inlet connection to the flowmeter is in the bottom end fitting The connections are normally horizont...

Страница 16: ...ion Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Model 1350E VB Valve Inlet with Aluminum Bezel Figure 2 2 Dimensions Sho Rate 1350E Model 1350E V Valve Inlet Cartridge Open Cartridge Open Inches Milimeters ...

Страница 17: ... 62 41 1 1 91 48 5 1 4 Rc 1 81 46 0 1 91 48 5 3 8 Rc 2 09 53 1 2 35 59 7 1 00 25 4 F E 2 13 54 0 45 0 3 00 76 0 DET SCALE SHOWN OPTIONAL 1 25 31 8 32 8 0 36 0 MTG BRACKET R0TATABLE ADJUSTABLE SQ DIMENSIONS ARE INCH MM 2 HOLES A 1350 1355 SHO RATE 12 3 0 35 9 0 2 00 51 0 OUTLET CONN D B 1 38 35 0 32 8 0 INLET CONN 8800 FLOW CONTROLLER 50 12 7 1 12 28 6 1 42 36 0 1 77 MAX C 1 42 MIN REGULATING VALVE...

Страница 18: ...llation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Model 1355E VB Valve Inlet with Aluminum Bezel Figure 2 4 Dimensions Sho Rate 1355E Model 1355E V Valve Inlet 8 81 224 8 81 224 Cartridge Open Cartridge Open Inches Milimeters ...

Страница 19: ...edle control valve may be provided to control the flow through the flowmeter These control valves are designed for fine control Excessive tightening may damage the valve seat and limit its effectiveness as a control valve If tight shut off is required it is recommended that a separate shut off valve should be installed in the line immediately before the flowmeter Flow indication is measured using ...

Страница 20: ...3 2 Models 1350E and 1355E Section 3 Operation Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 21: ...4 1 Disassembly and Cleaning It is recommended the user periodically inspect the tube and float and clean if necessary Dirt or foreign materials adhering to the tube and float may cause inaccuracy and sticking of the float The metering tube Borosilicate glass and related parts may be cleaned with any solvent which does not attack glass ...

Страница 22: ...4 2 Models 1350E and 1355E Section 4 Maintenance Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 THIS PAGE WAS INTENTIONALLY LEFT BLANK ...

Страница 23: ... List Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 5 1 General When ordering parts please specify Brooks Serial Number Model Number Part Number Description and Quantity Refer to Figure 5 1 and Table 5 1 ...

Страница 24: ...5 2 Models 1350E and 1355E Section 5 Parts List Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Figure 5 1 Parts Drawing Sho Rate Models 1350E and 1355E ...

Страница 25: ...5 3 Models 1350E and 1355E Section 5 Parts List Installation and Operation Manual X VA 1350E eng Part Number 541B082AAG February 2011 Table 5 1 Parts List Sho Rate Models 1350E and 1355E ...

Страница 26: ...is longer This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller BROOKS SERVICE AND SUPPORT Brooks is committed to assuring all of our customers receive the ideal flow solution for their application along with outstanding service and support to back it up We operate first class repair facilities located around...

Отзывы: