background image

 

If the power pack Nano 2 is operated with two lamp bases, the proportionality of the 
modelling light can be ensured by setting its proportionality level one digit lower in 
relation to the other power packs in use (e.g.: level 2 instead of level 3). 

 
 

The following operating modes are possible: 

"P" 

Proportional modelling light with an output level up to 1200 J (with Nano 2) 
respectively 2400 J (with Nano A4). This operating mode (highest 
proportionality level) is recommended, when exclusively Nano power packs with 
the same output level are in use in one working session. 

"P1" 

Proportional modelling light with broncolor power packs up to 6400 J 

"P2" 

Proportional modelling light with broncolor power packs up to 3200 J 

 

(= ex works setting for Nano A4) 

"P3" 

Proportional modelling light with broncolor power packs up to 1600 J 
(= ex works setting for Nano 2) 

"P4/5"  If a power pack is operated at a relatively low output level, the halogen 

modelling light will be relatively weak and yellowish. To counteract this problem,  
the Nano power packs are equipped with two additional modelling light 
proportionality levels: "P4" for 800 J or less and "P5" for 400 J or less. Thus the 
brightness of the modelling light can be increased. 

"HI" 

All lamp bases operate at full modelling light power independent of flash output. 
This setting will allow video recordings using the modelling lamps.  

"LO" 

Lighting level is reduced for all lamps independent of the flash output to reduce 
power consumption and extend the burning life of the halogen lamps. 

 
 

Pressing the “mod” key (2) for 1 second when the modelling light is on will give direct 
access to the "HI" mode. To return to the previous mode briefly press the "mod" key. 

 
 

Highest possible proportionality settings when combining power packs of different 
output: 
 

 

 

Nano 2 
Topas A2 
Grafit 2, A2 
Mobil 

Nano A4 
Topas A4 
Grafit A4 

Topas A8 Evolution

 

Nano 2 
Topas A2 
Grafit 2, A2 
Mobil 

P3 

(or „P“ when only  

Nano 2 are in use) 

 

P2 

 

P1 

 

Nano A4 
Topas A4 
Grafit A4 

 

P2 

P2 

(or „P“ when only 

Nano A4 are in 

use) 

 

P1 

 

Topas A8 Evolution 

P1 P1 P1 

 

Example 1: A power pack Nano 2 is operated together with a power pack Topas A8 

Evolution. The modelling light is proportional when both are set to level 
"prop1". 

 

Содержание nano 2

Страница 1: ...1 Operating instructions Nano 2 Nano A4 www broncolor com ...

Страница 2: ...s if necessary Observe the safety instructions Contents Page Important safety instructions 3 Attention Read before starting up the power pack 3 Controls and displays 4 1 Application Nano 6 2 Start up 6 3 Energy control 6 4 Lamp base outlets 7 5 Modelling light 7 6 Release 9 7 Ready signals visual audible 10 8 Additional functions with settings 11 9 Basic settings Ex works 12 10 Protective faciliti...

Страница 3: ...olled before operating to avoid overheating of the cable 7 Always turn off the power pack before connecting or disconnecting any lamp bases 8 Always unplug appliance from electrical socket before cleaning and servicing and when not in use Never jerk cable to pull plug from socket Grasp plug and pull to disconnect 9 Let appliance cool completely before putting away Loop cable loosely around applian...

Страница 4: ...thout the protecting glass in place Flash light contains similar to sunlight a specific portion of UV light The undesirable side effects on skin and eyes are considerably reduced by using flash tubes and glass covers with a UV coating Without these or other protective filters use with extreme care when shooting Even when disconnected from the power supply dangerous voltages may remain inside the u...

Страница 5: ... IR receiver on off 5 Buzzer on off 6 Slow charge on off 7 Charging dimmer on off 8 Operating mode modelling light 9 IR receiver cell 10 LED display for flash energy 11 Photocell 12 Energy control up down 13 Sync socket 14 1 Lamp base outlet 1 14 2 Lamp base outlet 2 15 Connection socket for mains cable 16 Fuse ...

Страница 6: ...6 1 30 70 100 2 16A T on off sync mod cell ir prop buz dim slow test 9 8 7 6 5 3 4 2 10 11 1 12 13 14 1 14 2 15 16 ...

Страница 7: ...ing time results b As a unit which is exclusively designed for a mains voltage of 100 120 V Please check if the local mains voltage corresponds with the indications on the label of the unit Make also sure that the halogen lamps modelling light of the connected lamp bases correspond with the indicated mains voltage 2 2 Earthed Mains AC line Connect unit to current supply always using earthed mains ...

Страница 8: ...e advantage that up to a maximum of 50 Nano 2 or 30 Nano A4 of the selected total energy can be triggered over the lamp base outlet 2 14 2 without needing to discharge the superfluous energy over the outlet 1 14 1 The fine adjustment is made by the flash voltage In this way the colour temperature with Nano 2 can be maintained constant within a range of 3 f stops and 100 K without overcharging the ...

Страница 9: ... this problem the Nano power packs are equipped with two additional modelling light proportionality levels P4 for 800 J or less and P5 for 400 J or less Thus the brightness of the modelling light can be increased HI All lamp bases operate at full modelling light power independent of flash output This setting will allow video recordings using the modelling lamps LO Lighting level is reduced for all...

Страница 10: ...vailable Please note however that the ready indicator is activated only at 100 charge chapter 7 6 1 Photocell cell and infrared receiver IR The photocell and the IR receiver can be switched on or off by using the cell IR key 4 If they are activated the green LED lights up 6 2 Infrared flash release channel You can trigger the Nano power packs from broncolor infrared transmitters If the power pack ...

Страница 11: ...y level of the modelling light can be selected by a brief pressure on the up down key 12 With repeated actuation of the key the following modes can be set each shown respectively on the digital display 10 P P1 P2 P3 P4 P5 HI LO After the setting has been performed the standard display can be re activated by pressing the prop key 8 or automatically after a waiting period of 10 seconds After return ...

Страница 12: ...s the function number 0 Now all other function numbers can be selected with the energy control up down keys 12 By briefly pressing the cell ir key 4 the digital display 10 will show you the actual values respectively the actual setting within the selected function number The LED of the cell ir and mod keys do not glow in this mode Within the function numbers 1 and 2 the settings can be changed by ...

Страница 13: ...r of the unit Figure group in the digital display xxXX 5 Series number of the unit Figure group in the digital display XXxx Return to normal operation by prolonged pressure the cell ir key by switching off and on again the unit or automatically after a waiting period of 20 seconds 10 Protective facilities Fault indication 10 1 Display th If excessively high temperatures build up inside despite the...

Страница 14: ...h off converter during pauses Charge battery if needed by allowing the car engine to run 1 Nano power pack can be connected to the converter 13 Lamp bases The following information applies to Pulso Primo and Picolite lamp bases 13 1 Replacing flash tubes Prior to any change of the flash tube the lamp base must be disconnected from the power pack Lamp bases use plug in flash tubes Normally the flas...

Страница 15: ...his warning sign on the lamp base plug when inserting the flash tube 13 1 2 Pulso 8 lamp base The flash tube is only available with a built in protection glass When exchanging the flash tubes or replacing the modelling lamp hold the flash tube carefully on the protecting glass and pull out in axial direction When inserting the flash tube check that the ceramic base is fully pushed back in If the P...

Страница 16: ...tion Should the lamp base overheat e g by impeding the flow of cooling air the modelling light is shut off Nevertheless you may continue producing flashes The Picolite however has an additional thermal protection which limits the number of flashes 13 5 Lamp base plugs The lamp base plugs and sockets have mechanical interlocks to prevent inadvertent disconnection When plugging in ensure that those ...

Страница 17: ...tribution Asymmetrical Controls Scratchproof keyboard and LED display Control range of flash energy Japan f stop less 4 f stops in 1 10 f stop intervals 1 16 switchable to 5 f stops 1 32 By selecting the corresponding lamp base outlet up to 6 f stops 1 64 with Nano 2 respectively up to 6 7 f stops 1 107 with Nano A4 Modelling light Halogen max 2 x 650 W at 200 240 V Halogen max 2 x 300 W at 100 12...

Страница 18: ...18 Bron Elektronik AG CH 4123 Allschwil Schweiz Switzerland Printed in Switzerland 11 05 ...