10
Example 2: A power pack Nano A4 is operated together with a power pack Grafit A2.
The modelling light is proportional and highest possible when both are set
to level "prop2".
5.3
Modelling light switch on lamp base
The switch on the lamp base permits selective lighting control with the modelling light.
To avoid damage to the lamp filament, always switch off the modelling light before
moving the lamp bases.
6. Release
The flash release is enabled when 75 % of the selected energy is available. Please
note, however, that the ready indicator is activated only at 100 % charge (chapter 7).
6.1
Photocell (cell) and infrared receiver (IR)
The photocell and the IR receiver can be switched on or off by using the "cell/IR" key
(4). If they are activated the green LED lights up.
6.2
Infrared flash release channel
You can trigger the Nano power packs from broncolor infrared transmitters. If the power
pack is triggered via infrared, the flash is released after a transmission delay of
1/1000 s.
6.3
Sync socket (13)
Synchronous cables art. no. 34.111.00 or 34.112.00 may be plugged into the socket to
release flashes via cable.
6.4
"Test" key (3)
This key (3) allows manual release of the power pack.