Layer 3 Upgrade Procedures for FastIron IPv4 devices
Detailed procedures
3.
Verify that the Layer 3 software is present in the flash area you specified by entering the following command.
show flash
The “Compressed Pri Code size” or “Compressed Sec Code size” line should list the software. If the software is not correct,
perform
again.
4.
Enter the following command at the Privileged EXEC level of the CLI to reboot the device using the new software:
boot system
flash primary | secondary
where
primary
or
secondary
specifies the flash area. Go to
5.
If you normally boot the device from a TFTP or BootP server, enter the following command at the Privileged EXEC level of the
CLI to reboot the device using the new software:
boot system tftp | bootp
NOTE
If you are booting the device from a TFTP server through a
fiber
connection, use the CLI command
boot system tftp
<ip-address> <filename> fiber-port
.
6.
Verify that the device booted using the Layer 3 software by observing the boot messages. The “SW” area lists the software
running on the device. You also can display this information by entering the
show version
command.