78
Brocade FastIron Edge X-Series Hardware Installation Guide
Part Number: 53-1002499-02
Hardware Specifications
Device specifications
or system engineer.
NOTE
Cable installation and network configuration will affect overall transmission capability. The numbers provided above represent the
accepted recommendations of the various standards. For network-specific recommendations, consult your local Brocade reseller
or system engineer.
Power cords
All of the FastIron devices ship with US-compatible power cords unless otherwise specified at the time of order. United Kingdom- and
European-compatible power cords are also available.
For more details, refer to
10GBase-1310
MMF
LC connector for
XFP module
9
1310 nm
up to 200 meters
10GBase-CX4
Copper
CX4 connector for
XFP module
n/a
n/a
up to 15 meters
10GBase-ER
SMF
LC connector for
XFP module
9
1550 nm
up to 40000 (40
km)
10GBase-LR
SMF
LC connector for
XFP module
9
1310 nm
2 – 10000
(10km)
10GBase-SR
MMF
LC connector for
XFP module
62.5/125
160
2 – 26
MMF
62.5/125
200
2 – 33
MMF
50/125
400
2 – 66
MMF
50/125
500
2 – 82
MMF
50/125
2000
2 – 300
10GBase-ZR
SMF
LC connector for
XFP module
9
1550 nm
up to 80000 (80
km)
10GBase-ZRD
SMF
LC connector for
XFP module
9
1530.33 –
1561.42 nm
up to 80000 (80
km)
1.
SMF = Single Mode Fiber, MMF = Multi-Mode Fiber
2.
The TIA 568 building wiring standard specifies 160/500 MHz*km MMF (Multi-mode Fiber).
3.
The international ISO/IEC 11801 building wiring standard specifies 200/500 MHz*km MMF.
4.
The ANSI Fibre Channel specification specifies 500/500 MHz*km 50 micron MMF and 500/500 MHz*km
fiber has been proposed for addition to ISO/IEC 11801.
TABLE 5
Cable specifications (Continued)
Network Interface
Cable Type
1
Connector Type
Core
Diameter
(microns)
Modal
Bandwidth
(MHz*km) or
Wavelength
(nm)
Range (meters)