Displaying temperature information
Each management module contains two temperature sensors. By default, the system polls the temperature of each management
module every 60 seconds. You can display the current temperature of the management modules (and all other modules) by entering the
following command at any CLI level.
device# show chassis
...
Slot 9 Temperature: 31.0 deg-C
Slot 10 Temperature: 34.0 deg-C
...
Syntax:
show chassis
The output displays the temperature of the management modules.
Displaying switchover information
You can view the system log or the traps logged on an SNMP trap receiver, which includes Information about whether a switchover has
occurred. For Syslog messages related to hitless OS upgrade and hitless switchover, refer to the
FastIron Ethernet Switch Administration
Guide
.
To view the system log or the traps logged on an SNMP trap receiver, enter the following command at any level of the CLI.
device# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0
overruns)
Buffer logging: level ACDMEINW, 25 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Dynamic Log Buffer (50 lines):
0d14h43m52s:N:System: Module was inserted to slot 9
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m23s:N:System: Fan speed changed automatically to 3
0d14h43m20s:I:System: Interface ethernet 5/2, state up
0d14h43m19s:I:System: Interface ethernet 3/2, state up
0d14h43m19s:I:System: Interface ethernet mgmt1, state up
0d14h43m19s:I:System: Interface ethernet 6/13, state up
0d14h43m18s:I:System: Interface ethernet 4/1, state up
0d14h43m18s:I:System: Interface ethernet 2/13, state up
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:N:System: Fan speed changed automatically to 2
0d14h43m18s:I:System: Interface ethernet 1/13, state up
0d14h43m16s:N:powered On switch Fabric
0d14h43m09s:N:powered On switch Fabric
0d14h43m01s:I:Mgmt CPU1 slot 9 failed
0d14h43m01s:I:System: Warm start
0d14h43m01s:I:SNMP: read-only community added by from session FastIron SX 800
This output shows that one switchover occurred.
Monitoring management module redundancy
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
117
Содержание FastIron SX
Страница 10: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 10 Part Number 53 1003613 04 ...
Страница 12: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 12 Part Number 53 1003613 04 ...
Страница 46: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 46 Part Number 53 1003613 04 ...
Страница 80: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 80 Part Number 53 1003613 04 ...
Страница 118: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 118 Part Number 53 1003613 04 ...
Страница 158: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 158 Part Number 53 1003613 04 ...
Страница 164: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 164 Part Number 53 1003613 04 ...
Страница 172: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 172 Part Number 53 1003613 04 ...