If the temperature of any thermal plane falls below the low threshold for a fan speed, the fan decreases its speed to the next
lower speed. If the temperature of any thermal plane falls below the high threshold for the low speed, the fan operates at the low
speed.
If the temperature of any thermal plane exceeds the high temperature threshold for any of the fan speeds, the software sends a message
to the system log.
The table below outlines the default low and high temperature thresholds for each fan speed, as well as the operating level and noise level
of the fans at each fan speed.
TABLE 24
Default low and high temperature thresholds for thermal planes and fan speeds
Fan Speed
Description
Low Temperature
Threshold
High Temperature
Threshold
Fan Operating Level
(% of Capacity)
Fan Noise Level
4
High
50 ° C
80 ° C
100
78 dB
3
Medium
49 ° C
59 ° C
50
66 dB
2
Medium-low
48 ° C
58 ° C
37
63 dB
1
Low
N/A
57 ° C
25
56 dB
Command syntax
If desired, you can change the default low and high temperature thresholds for a particular thermal plane and fan speed. For example, to
change the low and high thresholds of the medium fan speed for the management module or modules to 56 ° C and 72 ° C,
respectively, enter the following command at the global CONFIG level of the CLI.
device(config)# fan-threshold mp speed-3 56 72
Syntax:
fan-threshold module
[
speed-1
high-threshold
] [
speed-2
low-threshold
high-threshold
] [
speed-3
low-threshold
high-
threshold
] [
speed-4
low-threshold
high-threshold
]
For the module parameter, specify one of the following:
•
lp
- Changes low and high temperature thresholds for the Interface modules.
•
mp
- Changes low and high temperature thresholds for the management module.
•
sfp
- (FSX 800 and FSX 1600 only) Changes low and high temperature thresholds for the switch fabric modules.
The fan speeds are as follows:
•
speed-1 - low
•
speed-2 - medium-low
•
speed-3 - medium
•
speed-4 - high (shutdown temperature)
For the
low-threshold
and
high-threshold
variables, you can specify any temperature in Centigrade. However, when changing low and
high temperature thresholds for a module’s fan speeds, remember that the low temperature threshold of a higher fan speed must be
lower than the high temperature threshold of the lower fan speed. Brocade establishes this guideline to ensure the fan speed stability.
For example, if you are changing the temperature thresholds for the management module’s high and medium-high fans speeds, the
Brocade device will accept the following values because the low temperature threshold for the high speed (67 ° C) is lower than the high
temperature threshold (72 ° C) for the medium-high speed.
Fan Speed
Low Temperature Threshold
High Temperature Threshold
High
67 ° C
82 ° C
Medium-high
57 ° C
72 ° C
Managing the cooling system
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
101
Содержание FastIron SX
Страница 10: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 10 Part Number 53 1003613 04 ...
Страница 12: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 12 Part Number 53 1003613 04 ...
Страница 46: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 46 Part Number 53 1003613 04 ...
Страница 80: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 80 Part Number 53 1003613 04 ...
Страница 118: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 118 Part Number 53 1003613 04 ...
Страница 158: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 158 Part Number 53 1003613 04 ...
Страница 164: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 164 Part Number 53 1003613 04 ...
Страница 172: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 172 Part Number 53 1003613 04 ...