108
Fabric OS Troubleshooting and Diagnostics Guide
53-1002751-01
Equipment status
10
Equipment status
You can display status for fans, power supply, and temperature.
NOTE
The number of fans, power supplies, and temperature sensors depends on the switch type. For
detailed specifications on these components, refer to the switch hardware reference manual. The
specific output from the status commands varies depending on the switch type.
Checking the temperature, fan, and power supply
1. Log in to the switch as admin.
2. Enter the sensorShow command. Refer to the
Fabric OS Command Reference
for details
regarding the sensor numbers.
3. Check the temperature output.
Look for indications of high or low temperatures.
4. Check the fan speed output.
If any of the fan speeds display abnormal RPMs, replace the fan FRU.
5. Check the power supply status.
If any power supplies show a status other than OK, consider replacing the power supply as
soon as possible.
Checking the status of the fans
1. Connect to the switch and log in as admin.
2. Enter the fanShow command:
switch:admin>
fanshow
too shrt
Frames shorter than minimum
too long
Frames longer than maximum
bad eof
Frames with bad end-of-frame delimiters
enc out
Encoding error outside of frames
disc c3
Class 3 frames discarded
link fail
Link failures (LF1 or LF2 states)
loss sync
Loss of synchronization
loss sig
Loss of signal
frjt
Frames rejected with F_RJT
fbsy
Frames busied with F_BSY
TABLE 21
Error summary description (Continued)
Error type
Description
Содержание Fabric OS v7.1.0
Страница 4: ...iv Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...
Страница 10: ...x Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...
Страница 60: ...44 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Port mirroring 3...
Страница 66: ...50 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Brocade configuration form 4...
Страница 76: ...60 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Considerations for downgrading firmware 5...
Страница 136: ...120 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Switch Type and Blade ID A...
Страница 140: ...124 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Hexadecimal Conversion B...
Страница 146: ...130 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...