![Brocade Communications Systems Fabric OS v7.1.0 Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/brocade-communications-systems/fabric-os-v7-1-0/fabric-os-v7-1-0_troubleshooting-manual_2817316103.webp)
Fabric OS Troubleshooting and Diagnostics Guide
87
53-1002751-01
Using the SpinFab and portTest commands
10
Using the SpinFab and portTest commands
The spinFab command is an online diagnostics command to verify the ISL links between switches
at the maximum speed. It is done by setting up the routing functionality in the hardware such that
the test frames received by E_Port are retransmitted on the same E_Port. Several frames are then
sent to the port attached to each active E_Port specified. These frames are special frames which
never occur during normal traffic and the default action for such frames is to route them back to
the sender. These frames are circulated between switches until the test stops them.
CAUTION
During the spinFab testing, the switch remains in normal operation. However, some performance
degradation occurs due to the ISL links being saturated with the test frames. This test should be
run with caution on a live fabric.
Table 18
lists the supported ports for the specified version of Fabric OS when using the spinFab
command.
TABLE 18
Port type support
Port type
Supported in v6.3.0
Supported in v6.4.0
Supported in v7.1.0
Loopback
Yes
Yes
Yes
D_Ports
No
No
Yes
D_Ports to AG switch ports
No
No
Yes
E_Ports
Yes
Yes
Yes
Trunk Master ports
Yes
Yes
Yes
Ports beyond index 255
Yes
Yes
Yes
Ports with swapped areas
Yes
Yes
Yes
Shared-area ports
Yes
Yes
Yes
Ports in logical switches
Yes
Yes
Yes
Ports in base switches
Yes
Yes
Yes
Trunk slave ports
No
Yes
Yes
Long distance ports
No
Yes
Yes
F_Ports connected to Brocade HBAs
No
Yes
1
1.
If you use the
spinFab
command to test F_Ports connected to Brocade HBAs it is required that the
firmware version on the HBA is v2.1.1 or later.
Yes
2
2.
If you use the
spinFab
command to test F_Ports connected to Brocade HBAs it is required that the
firmware version on the HBA is v2.1.1 or later.
ICL ports
No
No
Yes
F_Ports connected to Access Gateway
No
No
Yes
EX_Ports
No
No
No
Ports in an Access Gateway switch
No
No
No
Содержание Fabric OS v7.1.0
Страница 4: ...iv Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...
Страница 10: ...x Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...
Страница 60: ...44 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Port mirroring 3...
Страница 66: ...50 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Brocade configuration form 4...
Страница 76: ...60 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Considerations for downgrading firmware 5...
Страница 136: ...120 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Switch Type and Blade ID A...
Страница 140: ...124 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Hexadecimal Conversion B...
Страница 146: ...130 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...