Fabric OS Troubleshooting and Diagnostics Guide
53-1002751-01
Diagnostic Port (D_Port)
10
Controlling testing
You can stop and start D_Port testing on a port by using the following respective commands:
•
portdporttest - -stop
[slot/]port
•
portdporttest - -start
[slot/]port
Available suboptions to the - --start option are as follows:
•
-nframes — Number of frames (in millions)
•
-framesize — Size of frame (from 36 to 2112 bytes)
•
-time — Test duration (in HH:MM format)
•
-pattern — A predefined pattern
•
-payload — A user-defined payload
•
-fec — Forward error correction (default is off)
•
-cr — Credit recovery (default is off)
In addition, the following options are available:
•
- -setarg — Allows you to set suboptions between tests or before automatic tests, with the same
options as with the - -start option.
•
- -restart — Allows you to use already-set parameters during current tests.
Example test scenarios and output
In addition to the examples shown in
“Enabling D_Port”
on page 95, other practiical scenarions are
shown below.
Confirming SFP and link status with an HBA
The steps in the following example illustrate how the command bcu diag - -dportenable will fail with
an SFP installed but without a connection to the switch.
1. Confirm the initial port status.
switch:admin>
bcu port --list
---------------------------------------------------------------------------
Port# FN Type PWWN/MAC FC Addr/ Media State Spd
Eth dev
---------------------------------------------------------------------------
1/0 - fc 10:00:8c:7c:ff:1c:e9:00 160000 sw Linkup 16G*
0 fc 10:00:8c:7c:ff:1c:e9:00 160000 sw Linkup 16G*
1/1 - fc 10:00:8c:7c:ff:1c:e9:01 -- sw Linkdown ---
1 fc 10:00:8c:7c:ff:1c:e9:01 -- sw Linkdown ---
---------------------------------------------------------------------------
2. Disable the port.
switch:admin>
bcu port --disable 1/0
port disabled
3. Remove the connection to the switch and attempt to enable the D_Port.
switch:admin>
bcu diag --dportenable 1/0
ERROR: Timer expired - Retry if persists contact support
Содержание Fabric OS v7.1.0
Страница 4: ...iv Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...
Страница 10: ...x Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...
Страница 60: ...44 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Port mirroring 3...
Страница 66: ...50 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Brocade configuration form 4...
Страница 76: ...60 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Considerations for downgrading firmware 5...
Страница 136: ...120 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Switch Type and Blade ID A...
Страница 140: ...124 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01 Hexadecimal Conversion B...
Страница 146: ...130 Fabric OS Troubleshooting and Diagnostics Guide 53 1002751 01...