Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 54 of 99
Defect ID:
DEFECT000386010
Technical Severity:
Medium
Summary:
Device does re-FLOGI with a different WWN cause stale entry in Flogin DataBase
Symptom:
switch reports duplicate WWN and panic.
Feature:
Field Escalation
Function:
Panic / OOM
Probability:
Medium
Found in Release:
FOS6.4.2
Service Request ID:
700637,722117
Where Else Fixed:
FOS6.4.3
Defect ID:
DEFECT000386559
Technical Severity:
Medium
Summary:
Good EOF CRC errors
Symptom:
Customer is seeing C2-1006 and C2-1010 messages reporting internal link errors without
hardware fault. The issue are associated with Good EOF CRC errors: This defect tracks
SERDES tuning for FS8-18 in DCX on slot 12, FC8-16 on DCX4s in slot1,2,7...
Feature:
Field Escalation
Function:
ASIC Driver
Probability:
Low
Found in Release:
FOS6.4.1
Service Request ID:
704947
Where Else Fixed:
FOS6.4.3
Defect ID:
DEFECT000387601
Technical Severity:
Medium
Summary:
Embedded platform with internal CU port turned into G Port
Symptom:
This server lost access to the devices when internal CU port connected to HBA turned into
G_Port.
Feature:
8G ASIC Driver
Function:
ASIC Driver
Probability:
Medium
Found in Release:
FOS7.0.1
Defect ID:
DEFECT000389731
Technical Severity:
Medium
Summary:
FICON Emulation is not handling IU pacing updates properly
Symptom:
Customer would see aborts on the fabric, and the customer reports that they went down
because they were not getting frames fast enough from the 7500's.
Feature:
Field Escalation
Function:
FICON
Probability:
Medium
Found in Release:
FOS6.4.2
Service Request ID:
684047
FOS6.4.3,
Defect ID:
DEFECT000391046
Technical Severity:
Medium
Summary:
portledtest, portloopbacktest etc diag command are updated.
Symptom:
Failure is observed when running 'portledtest -npass 10', 'portloopbacktest -lb_mode 1'
test
Workaround:
No
Feature:
Field Escalation
Function:
Diagnostics
Probability:
High
Found in Release:
FOS7.0.1
Service Request ID:
712391