![Brocade Communications Systems Fabric OS v7.0.2 Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/brocade-communications-systems/fabric-os-v7-0-2/fabric-os-v7-0-2_release-note_2817373043.webp)
Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 43 of 99
Defect ID:
DEFECT000389202
Technical Severity:
Medium
Summary:
After changing F-port buffers via WebTools 0n 7800 cannot set buffers back to 8 (Default)
Symptom:
After set F-port buffer credits to 16 using WebTools > port admin (advanced mode) > F-port BB
credit, was unable to set it back to 8 and get the following error message:"Error when performing
specified action for port 1 - F-Port BB credits with value less than 9 is not allowed.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Web Management
Reported In Release:
FOS7.0.0
Service Request ID:
710385
Defect ID:
DEFECT000389391
Technical Severity:
Medium
Summary:
CLI portname -i 0-79 -f will cause the switch to panic
Symptom:
When user enters an index range with larger value than is actually present with portname -i -f
command, the switch panics.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Low
Function:
Panic / OOM
Reported In Release:
FOS6.4.2
Service Request ID:
711133
Defect ID:
DEFECT000389661
Technical Severity:
Medium
Summary:
VeriSign Code Signing Certificate update for Web Tools
Symptom:
WebTools will be considered an UN-trusted application to the user .
After the code fix, when launch WT first time with the updated certificate, a warning dialog will be
displayed. User can verify the certificate details (Issuer/Validity/Subject) by clicking “More
information” in dialog. Once user selects the checkbox “Always trust content….” and click on Run
button, warning message will not display in further login since it is consider as trusted application.
Risk of Fix:
Low
Feature:
WebMgmt
Probability:
High
Function:
Login / Session Management
Reported In Release:
FOS7.0.1
Defect ID:
DEFECT000389731
Technical Severity:
Medium
Summary:
FICON Emulation is not handling IU pacing updates properly
Symptom:
Observes aborts on the fabric with BR7500 and application fails.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
Medium
Function:
FICON
Reported In Release:
FOS6.4.2
Service Request ID:
684047
Defect ID:
DEFECT000389967
Technical Severity:
High
Summary:
Switch name server rejects RFT_ID request on NPIV ports
Symptom:
In FOS v7.0 and later,name server request " RFT_ID" for several NPIV ports are rejected with reason
0x05 (Logical Busy). Host cannot see device if it does not retry the request.
Risk of Fix:
Low
Feature:
FOS Software
Probability:
High
Function:
Fabric Services
Reported In Release:
FOS7.0.0
Service Request ID:
710571
Defect ID:
DEFECT000390209
Technical Severity:
Medium
Summary:
portledtest does not function as described in documentation
Symptom:
On Brocade6510, " portledtest -action" option does not give the LED pattern documented in help
page. No other functional impact.
Risk of Fix:
Medium
Feature:
FOS Software
Probability:
Medium
Function:
Diagnostics
Reported In Release:
FOS7.0.1
Service Request ID:
712387