Fabric OS Documentation Updates
37
53-1002063-09
bottleneckMon
5
-lthresh
latency
_
threshold
Specifies the severity threshold for latency that triggers an alert. The
threshold indicates the percentage of one-second intervals affected by the
bottleneck condition within the specified time window. The threshold is
expressed as the equivalent fraction between 0 and 1. The default value is
0.1. This parameter is valid only for latency alerts.
EXAMPLES
Add the following examples to the Example section:
To enable bottleneck detection on the logical switch with congestion alerts only:
switch:admin> bottleneckmon --enable -alert=congestion
To enable bottleneck detection on the logical switch with latency alerts only:
switch:admin> bottleneckmon --enable -alert=latency
To enable bottleneck detection on the logical switch with both congestion and latency alerts:
switch:admin> bottleneckmon --enable -alert
To change the bottleneck detection configuration on the logical switch to allow congestion alerts only:
switch:admin> bottleneckmon --config -alert=congestion
To change the bottleneck detection configuration on the logical switch to allow latency alerts only:
switch:admin> bottleneckmon --config -alert=latency
To change the bottleneck detection configuration on the logical switch to allow both congestion and
latency alerts:
switch:admin> bottleneckmon --config -alert
To change the bottleneck detection configuration on the logical switch to disable all alerts:
switch:admin> bottleneckmon --config -noalert
To change the bottleneck detection configuration on port 5 to allow congestion alerts only; overrides
switch-wide configuration:
switch:admin> bottleneckmon --config -alert=congestion 5
To change the bottleneck detection configuration on port 5 to allow latency alerts only; overrides
switch-wide configuration:
switch:admin> bottleneckmon --config -alert=latency 5
To change the bottleneck detection configuration on port 5 to allow congestion and latency alerts;
overrides switch-wide configuration:
switch:admin> bottleneckmon --config -alert 5
To change the bottleneck detection configuration on port 5 to disable alerts; overrides switch-wide
configuration:
switch:admin> bottleneckmon --config -noalert 5
The output of the
--status
display has been changed to indicate which type of alert is configured. In the
section "Switch-wide alerting parameters", the output now displays which type of alert is configured.
(Previously it only displayed whether or not alerts were enabled.) In the section "Per-port overrides for
alert parameters", the abbreviations "C" and "L" indicate "congestion" and "latency". The meanings of the
abbreviations "Y" (both alerts configured) and "N" (no alerts configured) remain unchanged.
Содержание Fabric OS v6.4
Страница 1: ...53 1002063 09 02 August 2012 Fabric OS Documentation Updates Supporting Fabric OS v6 4 x ...
Страница 4: ...iv Fabric OS Documentation Updates 53 1002063 09 ...
Страница 8: ...viii Fabric OS Documentation Updates 53 1002063 09 ...
Страница 12: ...xii Fabric OS Documentation Updates 53 1002063 09 ...
Страница 14: ...2 Fabric OS Documentation Updates 53 1002063 09 Documentation updates for Fabric OS v6 4 1 and later 1 ...
Страница 18: ...6 Fabric OS Documentation Updates 53 1002063 09 Documentation updates for Fabric OS v6 4 1 2 ...
Страница 20: ...8 Fabric OS Documentation Updates 53 1002063 09 Documentation updates for Fabric OS v6 4 1 3 ...
Страница 26: ...14 Fabric OS Documentation Updates 53 1002063 09 Documentation Updates for Fabric OS v6 4 1 and later 4 ...
Страница 54: ...42 Fabric OS Documentation Updates 53 1002063 09 serDesTuneMode 5 ...