16
Fabric OS Documentation Updates
53-1002063-09
perfUserMonitor
5
perfUserMonitor
The
perfUserMonitor
valueList parameter must be entered in hexadecimal format. Decimal values are
not permitted. Update the parameter description and example as follows:
OPERAND
valueList
Specifies up to four values that need to be captured from the frame contents. The
ValueList
values must be in hexadecimal notation.
SOFx frames are considered special cases. The Offset is specified as 0x0,
valueList
values are specified with:
0
SOFf
1
SOFc1
2
OFi1
3
SOFn1
4
SOFi2
5
SOFn2
6
SOFi3
7
OFn3
EXAMPLE
To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a
port:
switch:admin>
perfaddusermonitor 1/4 "4, 0xff, 0x22; 0x12, 0xff, 0x01"
User monitor #0 added
As a special case, to add a filter-based monitor for SOFi3 on a port:
switch:admin>
perfaddusermonitor 1/4 "0, 0xff, 6"
User monitor #1 added
switchName
A switch name can include up to
30
characters on all platforms running Fabric OS v.6.2.0 or later. On the
Brocade 300, 5100, 5300, and 5410 platforms running earlier firmware versions, the switch name can be
up to
31
characters long. On all other pre-Fabric OS v6.2.0 platforms, the name is limited to 15
characters.
When you configure a switch name with 31 characters on a switch running Fabric OS v 6.1 and upgrade
from v6.1.X to v 6.2, the login prompt and
switchShow
command may still show 31 characters. This
inconsistency is harmless and does not cause memory corruption. To resolve the inconsistency, you can
take one of the following actions:
•
Reboot the system after upgrade from v6.1.X to v 6.2. Wait for the switch to reboot and log in
after the switch has come back up. The switch name will show only 30 characters.
•
Do a firmware upgrade from v6.2 to 6.3. This upgrade involves a reboot. Wait for the switch to
reboot and log in after the switch has come back up. The switch name will show only 30
characters.
The behavior of the
switchName
command in Fabric OS v 6.4 is the same as in v6.3. Since you cannot
upgrade directly to from v6.1.x to v6.4, the issue of switch name inconsistency is not applicable to Fabric
OS v6.4.
Содержание Fabric OS v6.4
Страница 1: ...53 1002063 09 02 August 2012 Fabric OS Documentation Updates Supporting Fabric OS v6 4 x ...
Страница 4: ...iv Fabric OS Documentation Updates 53 1002063 09 ...
Страница 8: ...viii Fabric OS Documentation Updates 53 1002063 09 ...
Страница 12: ...xii Fabric OS Documentation Updates 53 1002063 09 ...
Страница 14: ...2 Fabric OS Documentation Updates 53 1002063 09 Documentation updates for Fabric OS v6 4 1 and later 1 ...
Страница 18: ...6 Fabric OS Documentation Updates 53 1002063 09 Documentation updates for Fabric OS v6 4 1 2 ...
Страница 20: ...8 Fabric OS Documentation Updates 53 1002063 09 Documentation updates for Fabric OS v6 4 1 3 ...
Страница 26: ...14 Fabric OS Documentation Updates 53 1002063 09 Documentation Updates for Fabric OS v6 4 1 and later 4 ...
Страница 54: ...42 Fabric OS Documentation Updates 53 1002063 09 serDesTuneMode 5 ...