682
Fabric OS Command Reference
53-1001764-01
portCfgShow
22
portCfgShow
Displays port configuration settings.
SYNOPSIS
portcfgshow
portcfgshow
[
slot
/]
port
portcfgshow -i
[
ndex1
[-
index2
] [...] [
-f
]]
portcfgshow -slot
slot1
[-
slot2
] [...]
portcfgshow
option
[
slot
/][
ge
_
port
] [
arguments
]
[
optional_arguments
]
DESCRIPTION
Use this command to display the current configuration of a port. The behavior of this command is
platform-specific; output varies depending on port type and platform, and not all options are supported on
all platforms.
Non-GbE port displays
When used without operands, this command displays port configuration settings for all ports on a switch,
except Gigabit Ethernet (GbE) ports.
Displays supported only on the Brocade 7800/FX8-24 and on the Brocade FR4-18i platforms
Use this command with optional arguments to display the following parameters configured for a GbE port
on the Brocade 7800/FX8-24 and on the Brocade FR4-18i platforms.
•
IP interfaces on the GbE port
•
Static routes on the IP interfaces
•
Address resolution protocol (ARP) entries
•
VLAN tag configuration
•
Fibre Channel over IP (FCIP) tunnel configuration settings
-
IPSec configuration
-
QoS mappings (Brocade FR4-18i only)
•
Port mode information (Brocade FR4-18i only)
Displays supported only on the Brocade 7800/FX8-24 platforms
•
Inband Management IP addresses and routes.
Non-GbE port displays
The following information is displayed when the command is issued for all ports, for a single port, or for
one or more port ranges specified by their port index numbers or slot numbers:
Area Number
Displays the port area number. This field is displayed only when portCfgShow is
executed for a single port.
Speed
Displays Auto for auto speed negotiation mode, or a specific speed of 1, 2, 4, or 8
Gbps. This value is set by the
portCfgSpeed
command.
Fill Word (On Active)
Displays the fill word setting that will take effect after the next time the port goes
offline and comes back Possible values are 0(Idle-Idle), 1(arbff-arbff), 2(Idle-arbff),
or 3(A-A then SW I-A).This parameter is set by the
portcfgFillword
command.
Содержание Brocade 8/12c
Страница 1: ...53 1002147 01 29 April 2011 Fabric OS Command Reference Manual Supporting Fabric OS v7 0 0 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002147 01 ...
Страница 34: ...xxxiv Fabric OS Command Reference 53 1002147 01 ...
Страница 124: ...90 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 275: ...Fabric OS Command Reference 241 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...