82
Fabric OS Command Reference
53-1001764-01
bpPortLoopbackTest
22
bpPortLoopbackTest
Sends and receives data from the same BP port to perform a functional test of the port.
SYNOPSIS
bpportloopbacktest
[
--slot
slot
]
[
-nframes
count
]
[
-pklen
count
]
[
-lb_mode
mode
]
[
-spd_mode
mode
]
[
-bpports
itemlist
]
DESCRIPTION
Use this command to verify the functional operation of the switch. The test sends frames from a specified
blade processor (BP) port transmitter and loops the frames back into the same BP port's receiver. The
path exercised in this test includes the connections from the BP chip to the Control Processor (CP) chip.
The test can be performed on a single port or on a range of BP ports.
Before running this diagnostic, you must disable the chassis and clear all logs using the following
command sequence:
1.
Execute
chassisDisable
2.
Execute
slotStatsClear
3.
Execute
diagClearError -all
4.
Execute
cryptoCfg --disableEE
(if the encryption engine is in enabled state)
By default, eight frames are transmitted and received on each port. The test method is as follows:
1.
Set all ports present for the loopback mode specified.
2.
Create a frame F of maximum data size (2112 bytes).
3.
Transmit frame F through the specified port.
4.
Pick up the frame from the same port.
5.
Check if any of the following statistic error counters report nonzero values: ENC_in, CRC_err,
TruncFrm, FrmTooLong, BadEOF, Enc_out, BadOrdSet, DiscC3.
6.
Check if the transmit, receive, or class 3 receiver counters are stuck at some value.
7.
Check if the number of frames transmitted is not equal to the number of frames received.
8.
Repeat steps two through seven for all specified ports until one of the following conditions is met:
a.
The number of frames (or nframes) requested is reached.
b.
All ports are marked bad.
Содержание Brocade 8/12c
Страница 1: ...53 1002147 01 29 April 2011 Fabric OS Command Reference Manual Supporting Fabric OS v7 0 0 ...
Страница 6: ...vi Fabric OS Command Reference 53 1002147 01 ...
Страница 34: ...xxxiv Fabric OS Command Reference 53 1002147 01 ...
Страница 124: ...90 Fabric OS Command Reference 53 1001764 01 ceePortLedTest 22 ceePortLedTest DESCRIPTION See portLedTest SEE ALSO None ...
Страница 275: ...Fabric OS Command Reference 241 53 1001764 01 exit 22 exit DESCRIPTION See logout SEE ALSO None ...