415/240 Volt Main
power supply.
Inability to isolate power supply during cleaning
or maintenance, injury risk, electric shock,
electrocution risk to operator or repair personnel.
Failure of circuit protection to activate in the
event of metallic frames becoming live.
R
ISK
S
CORE
:
5:4:4
V
Introduce “Plug lockout calliper system” to isolation and “lockout” / “tagout”
procedure to site maintenance procedures. Attach site maintenance procedures to site
safety induction policy & induction for maintenance personnel. Include item to “Test &
Tag” AS / NZS 3760 periodic test register. Carry out insulation leakage tests to all
hazardous voltage, mains power electric components and associated metal work.
Check earth continuity / resistance to all metal frames and attachments. Provide or
repair earth points as necessary in accordance with AS 3000 & AS/NZ 3760
5:2:3=M
415/240 volt power
supply.
Electric shocks, burns, electrocution risks.
R
ISK
S
CORE
:
6:5:4
V
Fit “DANGEROUS VOLTAGE,” and or ISO international symbol signs to all access
covers over dangerous voltage areas of unit. Adequate warning of dangerous voltages
within must be provided at all areas.
6:1:2=L
Standby operation of
saw.
Accidental operation of saw during servicing,
setup or adjustment. Severing, cutting, electrical
shock injury risks.
R
ISK
S
CORE
:
4:3:4
M
Fit “STAND BY” warning indicator circuit and tell tale lamp to saw in proximity to “ON /
OFF“ switch.
4:3:2=L
Plant maintenance.
Unauthorized and untrained personnel carrying
out plant maintenance, personnel injuries.
Risk Score: 5:4:4
V
Introduce “No unauthorized personnel to carry out maintenance to plant” policy to site
induction training.
5:2:2=L
Содержание S315D, S350D, S400B
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ...THREE PHASE ONE PHASE COMPONENT SCHEMATIC WIRING DIAGRAMS FOR CONNECTION FOR 1 PHASE OR 3 PHASE CIRCUIT ...
Страница 26: ......
Страница 27: ...ELECTRICAL DIAGRAM 2 Speed Switch 1 0 2 ...
Страница 55: ......