background image

ZB80L1 

n

 

 

ZB110L1 Installation Guide

Page 13

5

10

12

1

3

6

7

4

8

9

11

13

2

Warranty

Service Parts

Order replacement 

parts by

 Part No.

not by 

Key No.

  Key No.   Part No. 

Description

 

97018349 

Mounting Frame

 

97018721 

Knockout Plate & Screws

  3 

97018382 Housing

 

97020893 

Wiring Panel/Harness Assembly 

 

97020846 

Control Assembly & Motor 

(ZB80L1)

 

 

97020845 

Control Assembly & Motor 

(ZB110L1)

 

97018331 

Duct Connector - 6"

 

99111513 

6" to 4" Reducer 

(model ZB80L1 only)

 

99020301 

Blower Wheel

 

97018768 

Scroll Assembly 

(ZB110L1)

  

97019371 

Scroll Assembly 

(ZB80L1)

  10 

97020827 

Grille Assembly 

(includes 11, 12)

  11 

99140208 

Grille Spring 

(2 req’d)

 12 

99111711  Lens 

(2 req’d)

  13 

99271625 

LED Driver

Broan Ventilation Fan/Lights Limited Warranty 

WARRANTY PERIOD: Broan warrants to the original consumer purchaser 

of its Broan Ventilation Fan/Light (the “Fan”) that your Fan (excluding lamps/

bulbs) will be materially free from defects in materials or workmanship for a 

period of three (3) years from the date of original purchase. The warranty on 

the lamps/bulbs provided with the Fan is one (1) year and does not cover 

lamp/bulb breakage. This warranty does not cover accessories, such as 

speed controls, that may be purchased separately and installed with the Fan.

The limited warranty period for replacement parts, and for Fans repaired or 

replaced under this limited warranty, shall continue for the remainder of the 

original warranty period.

NO OTHER WARRANTIES: THE FOREGOING WARRANTIES ARE 

EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR 

IMPLIED. BROAN DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS 

WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES 

IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO 

THE EXTENT THAT APPLICABLE LAW PROHIBITS THE EXCLUSION 

OF IMPLIED WARRANTIES, THE DURATION OF ANY APPLICABLE 

IMPLIED WARRANTY IS LIMITED TO THE PERIOD SPECIFIED FOR THE 

EXPRESS WARRANTY. Some states do not allow limitations on how long an 

implied warranty lasts, so the above limitation may not apply to you. Any oral 

or written description of the Fan is for the sole purpose of identifying it and 

shall not be construed as an express warranty.

REMEDY: During the applicable limited warranty period, Broan will, at its 

option, provide replacement parts for, or repair or replace, without charge, 

any Fan or part thereof, to the extent Broan finds it to be covered by and in 

breach of this limited warranty. Broan will ship the repaired or replaced Fan 

or replacement parts to you at no charge. You are responsible for all costs 

for removal, reinstallation and shipping, insurance or other freight charges 

incurred in the shipment of the Fan or part to Broan. This warranty does not 

cover (a) normal maintenance and service, (b) normal wear and tear, (c) any 

Fans or parts which have been subject to misuse, abuse, abnormal usage, 

negligence, accident, improper or insufficient maintenance, storage or repair 

(other than repair by Broan), (d) damage caused by faulty installation, or 

installation or use contrary to recommendations or instructions, (e) any Fan 

that has been moved from its original point of installation, (f) damage caused 

by environmental or natural elements, (g) damage in transit, (h) natural wear 

of finish, (i) Fans in commercial or nonresidential use, or (j) damage caused 

by fire, flood or other act of God. This warranty covers only Fans sold in the 

United States or through U.S. distributors authorized by Broan. 

EXCLUSION OF DAMAGES: BROAN’S OBLIGATION TO PROVIDE 

REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT BROAN’S 

OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER 

THIS LIMITED WARRANTY AND BROAN’S SOLE AND EXCLUSIVE 

OBLIGATION. BROAN SHALL NOT BE LIABLE FOR INCIDENTAL, 

INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT 

OF OR IN CONNECTION WITH THE FAN, ITS USE OR PERFORMANCE. 

Incidental damages include but are not limited to such damages as loss of 

time and loss of use. Consequential damages include but are not limited to 

the cost of repairing or replacing other property which was damaged if the 

Fan does not work properly. 

Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation or exclusion may not apply 

to you. This warranty gives you specific legal rights, and you may also have 

other rights, which vary from state to state. 

This warranty supersedes all prior warranties and is not transferable from 

the original consumer purchaser. 

BROAN SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING 

UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, 

INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES 

ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, 

NEGLIGENCE OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, 

WITH RESPECT TO THE FAN OR BROAN’S ACTS OR OMISSIONS OR 

OTHERWISE. 

This warranty covers only replacement or repair of defective Fans or parts 

thereof at Broan’s main facility and does not include the cost of field service 

travel and living expenses.

Any assistance Broan provides to or procures for you outside the terms, 

limitations or exclusions of this limited warranty will not constitute a waiver 

of such terms, limitations or exclusions, nor will such assistance extend or 

revive the warranty.

Broan will not reimburse you for any expenses incurred by you in repairing 

or replacing any defective Fan, except for those incurred with Broan’s prior 

written permission.

HOW TO OBTAIN WARRANTY SERVICE: To qualify for warranty service, 

you must (a) notify Broan at the address or telephone number stated below 

within seven (7) days of discovering the covered defect, (b) give the model 

number and part identification and (c) describe the nature of any defect in 

the Fan or part. At the time of requesting warranty service, you must present 

evidence of the original purchase date. 

Broan, 926 West State Street, Hartford, WI  53027  

(1-800-637-1453)

www.broan.com

If you must send the Fan or part to Broan, as instructed by Broan, you must 

properly pack the Fan or part—Broan is not responsible for damage in transit.

Содержание ZB110L1

Страница 1: ... with homeowner Register your product online at www broan com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 12 Service Parts 13 Warranty 13 2017 Broan ...

Страница 2: ... connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 To ...

Страница 3: ...er with a Phillips bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 1 Remove Packaging ...

Страница 4: ...and Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting snap ...

Страница 5: ... 2 14 3 FAN SWITCH MODE SELECT SWITCH LIGHT LIGHT WITH DIMMER SWITCH New Construction Installation 5 Connect Wires and Install Knockout Plate Run 120VAC electrical wiring to the installation location Use proper UL approved connectors to secure wiring to the Knockout Plate provided in Parts Bag Connect wires as shown in wiring diagram Screw from Parts Bag Attach cable clamps to Knockout Plate Knock...

Страница 6: ...stall Grille Mask protects unit during construction Remove before installing Grille Install ceiling material Cut out around Housing CAUTION If the blower was unplugged power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE 1 2 3 1 ...

Страница 7: ... existing wiring to make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from packaging See Step 12 1 Remove Packaging 2 Switch Off Power 4 Examine Wiring 3 Enlarge Ceiling Opening and Remove Existing Fan Ruler Pencil Drywall saw Claw hammer or pry bar Utility knife Materials ...

Страница 8: ...3 4 5 1 1 2 3 3 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Remove screws from Mounting Frame and set aside ...

Страница 9: ...e in Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure Mounting Frame 9 Snap in Housing snap 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting ...

Страница 10: ...ect wires as shown in wiring diagram Attach cable clamps to Knockout Plate Knockout Plate mounts to inside of Housing and may be oriented as desired LINE IN GRD WHT BLK GRD WHT WHT WHT BLK BLK BLU RED BLK LIGHT SWITCH FAN SWITCH FAN LIGHT UNIT SWITCH BOX RED WHT 14 2 14 3 MANUAL ON DIMMER SWITCH LINE IN GRD WHT BLK GRD WHT WHT WHT BLK BLK BLU RED BLK MASTER ON OFF SWITCH FAN UNIT SWITCH BOX RED WH...

Страница 11: ...ille If ceiling repairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag CAUTION Power must be disconnected see page 2 WARNING item 2 before inserting motor plugs into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE ...

Страница 12: ...y be operated with a dimmer switch See wiring diagrams Cleaning and Maintenance To Clean For quiet and efficient operation long life and attractive appearance remove Grille and vacuum interior of unit with a dusting brush attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Control Assembly and Motor Troubles...

Страница 13: ...nance storage or repair other than repair by Broan d damage caused by faulty installation or installation or use contrary to recommendations or instructions e any Fan that has been moved from its original point of installation f damage caused by environmental or natural elements g damage in transit h natural wear of finish i Fans in commercial or nonresidential use or j damage caused by fire flood...

Страница 14: ...ZB80L1 n ZB110L1 Installation Guide Page 14 99045910A ...

Страница 15: ...de casa Registre su producto en línea en el sitio www broan com register Instalación sencilla tanto en construcciones nuevas como en modernizaciones Tabla de contenido Advertencias y precauciones 2 Instalación típica 2 Instalación en una construcción nueva 3 Instalación en modernizaciones 7 Funcionamiento 12 Limpieza y mantenimiento 12 Identificación y solución de fallas 13 Repuestos 13 Garantía 1...

Страница 16: ...llas con conexión a tierra ICFT 9 Esta unidad debe estar conectada a tierra Instalación típica PRECAUCIÓN 1 Sólo debe utilizarse para ventilación general No utilizar para ventilar materiales y vapores peligrosos o explosivos 2 Este producto está diseñado para instalarse en techos con una pendiente de hasta 12 12 ángulo de 45 grados El conector del conducto debe estar orientado hacia arriba NO MONT...

Страница 17: ...Destornillador de cabeza plana Pinza Pelacable para la aislación de los cables Pinza cortacable Materiales necesarios Conducto circular de metal de 6 pulg recomendado para un mejor rendimiento Se acepta el uso de otro tipo de conducto pero esto puede afectar el rendimiento Capuchón para tejado o de pared se recomienda utilizar uno con regulador de tiro incorporado Cinta para sellar las conexiones ...

Страница 18: ...anal a ambos lados del bastidor de montaje para que el compartimiento quede asegurado en su lugar No ajuste el compartimiento Pernos de la bolsa de piezas Las bridas superior e inferior deben ir por fuera del compartimiento Introduzca la pestaña en la ranura en el interior del compartimiento Perno de la bolsa de piezas Algunos modelos cuentan con un adaptador de 6 a 4 pulg Cinta Cinta Cinta Conduc...

Страница 19: ...metálica Extienda un cableado eléctrico de 120 VCA hasta el sitio de la instalación Utilice conectores aprobados por UL para asegurar el cableado hasta la placa metálica que se incluye en la bolsa de piezas Conecte los cables como se muestra en el diagrama de cableado Perno de la bolsa de piezas Fije las abrazaderas de los cables a la placa metálica La placa metálica debe montarse en el exterior d...

Страница 20: ...a protege la unidad durante la construcción Retírela antes de instalar la rejilla Instale el material del techo Corte alrededor del compartimiento PRECAUCIÓN Si el motor estaba desconectado se debe desconectar la electricidad vea la página 2 ADVERTENCIA punto 2 antes de insertar los enchufes del motor en el conjunto de control PARA PREVENIR DAÑOS EN EL MOTOR CONTROL 1 2 3 1 ...

Страница 21: ...ún daño NO CONTINÚE CON LA INSTALACIÓN de este producto Comuníquese con la s persona s calificada s para realizar la reparación Retire la hoja de instrucciones Retire la máscara del envase Consulte el Paso 12 1 Retire el envase 2 Desconecte el suministro de energía 4 Verifique el cableado 3 Aumente la abertura del techo y retire el ventilador existente Regla Lápiz Sierra para paneles de yeso Marti...

Страница 22: ...rnizaciones 5 Retire el conjunto del ventilador 6 Retire el panel con los cables 7 Introduzca el bastidor de montaje Ambos lados Aparte el conjunto del ventilador Aparte el panel con los cables Aparte el perno Despliegue las cuatro pestañas Retire los pernos del bastidor de montaje y apártelos ...

Страница 23: ...e en el bastidor de montaje Introduzca el conducto existente en el compartimiento Introduzca la pestaña en la ranura que se encuentra en el interior del compartimiento 10 Fije el conector del conducto y los conductos 8 Asegure el bastidor de montaje 9 Coloque el compartimiento a presión Cinta Cinta Cinta Presione hasta que trabe Algunos modelos cuentan con un adaptador de 6 a 4 pulg Conducto de 6 ...

Страница 24: ...ra asegurar el cableado hasta la placa metálica que se incluye en la bolsa de piezas Conecte los cables como se muestra en el diagrama de cableado LINEA DE ENTRADA TRA BLC NEG TRA BLC BLC BLC NEG NEG AZL ROJ NEG INTERRUPTOR PRINCIPAL DE ENCENDIDO APAGADO VENT LUZ UNIDAD CAJA DE INTERRUPTORES ROJ BLC 14 2 14 3 INTERRUPTOR DE SELECCIÓN DE MODO INTERRUPTOR DE VENTILATOR REGULADOR DE INTENSIDAD LUZ CO...

Страница 25: ... en el techo coloque la máscara en el compartimiento después de asegurar el conjunto del ventilador Consulte el Paso 6 de Instalación en una construcción nueva Retire la máscara antes de instalar la rejilla Pernos de la bolsa de piezas PRECAUCIÓN PARA PREVENIR DAÑOS EN EL MOTOR CONTROL Debe desconectar la electricidad vea la página 2 ADVERTENCIA punto 2 antes de insertar los enchufes del motor en ...

Страница 26: ...udal de aire ajustable por el usuario Utilizando un destornillador pequeño de punta plana haga girar con cuidado el ajuste de pies cúbicos por minuto CFM hasta que la flecha indique el índice del caudal de aire deseado Determinación del retardo del tiempo ajustable por el usuario Utilizando un destornillador pequeño de punta plana haga girar con cuidado el ajuste del tiempo TIME hasta que la flech...

Страница 27: ...s e insectos Síntoma El ventilador no ventila el ambiente en forma correcta Para ventilar el sitio encienda el interruptor principal y el interruptor selector de modo para permitir que el ventilador funcione al índice de caudal de aire certificado Para ventilar el sitio después de la ventilación continua aumente la configuración del tiempo del retardo del tiempo ajustable por el usuario Para la ve...

Страница 28: ...ación u otro caso fortuito Esta garantía cubre sólo a los Ventiladores que se venden en los Estados Unidos o a través de representantes de los Estados Unidos autorizados por Broan EXCLUSIÓN DE DAÑOS LA OBLIGACIÓN DE BROAN DE PROPORCIONAR REPUESTOS O LA REPARACIÓN O EL REEMPLAZO A DISCRECIÓN DE BROAN SERÁ LA ÚNICA Y EXCLUSIVA COMPENSACIÓN BAJO EL AMPARO DE ESTA GARANTÍA LIMITADA Y LA ÚNICA Y EXCLUS...

Отзывы: