![Broan VX12000C Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/broan/vx12000c/vx12000c_installation-tips-and-user-manual_2816599006.webp)
page 6
FITTING MAIN LINE TO POWER UNIT
Your power unit is capable of being connected to the intake
vacuum trunk line from either side. Select the intake
connection to be used. Some installations may require the
connection into both intakes. The power unit has 4 intake
connections, which 2 of them are factory capped.
1. Using rubber coupling and hose clamp provided, attach the
utility valve assembly to the vacuum trunk line feeding into
the power unit. The utility valve can be installed on the left
or right hand side.
2. Cap off the unused intake tube with the plastic cap provided.
3. Attach exhaust tube to power unit using rubber coupling
and hose clamp provided (if vented to the outside).
4. Make sure all tubing connections are air tight.
5. The exhaust should NOT be vented into a wall, ceiling or
concealed space in the house. It is recommended to vent
the vacuum exhaust air to the outside of the house.
Exterior vented exhaust lines should be terminated using
Model V142 wall caps.
DIMENSIONAL CHART
EXHAUST
“B” CENTER OF EXHAUST
TO MOUNTING
BRACKET HOLES
“A”
OVERALL
HEIGHT
“C”
INTAKE
AD0004A
Models
VX3000C
VX6000C
VX12000C
A
36
9
⁄
16
”
39
9
⁄
16
”
39
9
⁄
16
”
B
11”
11”
11”
C
10
7
⁄
8
”
10
7
⁄
8
”
10
7
⁄
8
”
CAUTION
Broan VX3000C, VX6000C and VX12000C power
units will attach to the lower intake connections.
See Fig. 10
.
Utility valve can be installed on either
side.
INTERNAL
WIRING DIAGRAMS
• VX3000C • VX6000C
AE0005A
WHITE
WHITE
BLACK
BLACK
GREEN
GREEN
120 VOLTS
MOTOR
CONTROL
YELLO
W
YELLO
W
THERMAL
PROTECTOR
CONTROL
BOARD
BLUE
BLUE
AE0027A
RED OR WHITE
RED OR WHITE
RED OR WHITE
BLACK
BLACK
BLACK
BLACK
BLUE
GREEN
GREEN
GREEN
GREEN
YELLO
W
YELLO
W
MOTOR
MOTOR
CONTROL
CONTROL
BOARD
THERMAL
PROTECTOR
240 VOLTS
BLUE
THERMAL
PROTECTOR
BLUE
BLUE
• VX12000C
POWER UNIT
INSTALLATION
(
CONT
’
D
)