![Broan VX12000C Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/broan/vx12000c/vx12000c_installation-tips-and-user-manual_2816599005.webp)
page 5
MOUNTING
Your power unit mounts to the wall using a mounting system.
The wall mounting bracket, provided with your power unit,
mounts to the wall. It has 4 fingers at the top and 4 more at the
bottom. The power unit has 4 upper openings and 4 lower
openings which are designed to slide onto the wall mounting
bracket fingers. Ensure to follow the instructions below for
proper installation.
1. Locate power unit within six feet (1.82 m) of a grounded
electrical outlet. Broan VX3000C and VX6000C power
units require a 120 V, dedicated 15-amp branch-circuit with
a NEMA 5-15R receptacle or a dedicated 20-amp branch
circuit with a NEMA 5-20R receptacle. Broan VX12000C
power unit requires a 240 VAC, dedicated 20-amp branch
circuit with a NEMA 6-20R receptacle.
2. Refer to
Fig. 2
to maintain minimum wall clearance
dimensions.
3. Position and install the wall mounting bracket with the
provided screws. Refer to
Fig. 3
for proper mounting
dimensions.
4. Using the provided mounting screws, secure the mounting
bracket on the wall through two upper and two lower
mounting holes.
5. Hang power unit onto wall mounting bracket. Ensure both
upper and lower mounting openings on the back of the
power unit are engaged with corresponding wall bracket
fingers. Pull the power unit down to secure.
6. Open the door located on the front of the power unit.
Ensure the cyclonic filter is properly seated.
See page 13 for reference. Close the door.
12⅝”
3/4” TYP.
30¾”
1” TYP.
43
7
⁄
16
”
MIN.
HEIGHT
30¼”
30⅜”
30⅜”
MOUNTING
HOLES
MOUNTING
HOLES
AD0044A
CAUTION
Ensure to fix the wall mounting bracket with the
screws directly onto a stud for a solid installation.
CAUTION
For all models, DO NOT REMOVE either of the TOP
red cap plugs that are glued to the unit. Removing
these glued plugs will damage the unit. Only
remove and use the outlets covered by the green
BOTTOM plugs.
WARNING
Do not install outdoors.
!
AD0050A
Broan VX3000C: 11”
Broan VX6000C and VX12000C: 13¾”
FRONT VIEW
UTILITY
VALVE
24”
MINIMUM TO CEILING
18” MINIMUM
ABOVE FLOOR
24”
24”
TOP VIEW
WALL MINIMUM CLEARANCE DIMENSIONS
F
IG
. 2
F
IG
. 3
POWER UNIT
INSTALLATION