AC0001

VACUUM POWER CONTROL

The wand end of the deluxe hoses is equipped with a control
ring to regulate suction. The control ring covers a “bleeder”
hole. Open the hole to reduce the suction for cleaning
draperies, small rugs, and other light fabrics. Some very thick,
plush carpets with high density yarns also require reduced
suction to make the nozzle easier to push. Be sure to close the
control ring completely over the hole to produce the maximum
power required for most other cleaning tasks.

WHEN TO EMPTY THE DEBRIS PAIL

Broan model VX3000C has a single indicator light that
remains green. The level of pail fill for this model can be 
determined by either viewing through the window on the pail or
releasing the carry handles and checking the level of debris in
the pail. 

Broan models VX6000C and VX12000C have the LED 
indicators that show the status of the level of debris in the pail.
The first three lights remain green as pail fills. The fourth light
is amber and will come on to alert you that the pail is nearly
full. When the fifth light turns red it is time to empty the pail
(see CONTROL PANEL DIAGRAM A below).

EMPTYING THE DEBRIS PAIL

Your power unit has a permanent filter that is self cleaning
under normal conditions. The filter protects the motor and
stops small dirt particles from escaping to the outside of the
power unit. The filter cleans itself by moving up when the
power unit starts, and dropping down when the unit is turned
off. The filter can be removed by means of a pull-tab for 
cleaning if desired. Be sure to reinstall properly. Correct 
placement is critical to insure proper protection for the motor.

1. Release both carry handles on side of the unit by pulling

out and then pushing up. (

Fig. 10

). Holding the pail by the

handles, lower it from unit (

Fig. 11

).

2. Carry pail to trash receptacle and empty. 

3. Reattach pail using handles.

4. Push 

Reset

button on control panel. Light on control panel

will change to green on Broan models VX6000C and
VX12000C.

Utility valve (circled in 

Fig. 11

), next to power unit, can be

used to service area around where power unit is installed.

G

REEN

O

NLY

Broan VX3000C

Manually check

pail to determine 

fill level.

G

REEN

A

MBER

R

ED

R

ESET

Broan VX6000C 

and VX12000C

Timed pail 

full indicators

CONTROL PANEL DIAGRAM A

AR0001

AR0002

FOR ALL MODELS

F

IG

. 10

F

IG

. 11

Содержание VX12000C

Страница 1: ...R GUIDE BROAN NUTONE CANADA INC MISSISSAUGA ONTARIO WWW BROAN CA 1 888 882 7626 30042323 rev K CENTRAL VACUUM POWER UNIT REGISTER YOUR PRODUCT ONLINE AT WWW BROAN CA FOR RESIDENTIAL USE ONLY VISIT WWW BROAN CA FOR THE CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS ...

Страница 2: ... unit by pulling on cord To unplug grasp the plug not the cord 11 Store your cleaner indoors in a clean dry area 12 Any servicing other than that recommended in this manu al should be performed by an authorized service facility 13 We recommend that your unit be inspected by a specialized technician once a year OPERATION The power unit is located away from the everyday living areas of your home usu...

Страница 3: ...PARTS 15 WARRANTY 16 TABLE OF CONTENTS CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS Please visit www broan ca for the Central Vacuum System Installation Instructions including System Planning and Layout General Installation Installation in New Construction Installation in Existing Construction Tubing System Assembly Final System Check Also including the practical and easy to use Vacusweep Inlet...

Страница 4: ... or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE WIRE TO TUBING The low voltage power wiring is run along with the tubing Use electrical tape to secure the wire to the tubing Tape the wire approximately every 12 to 18 MAKING THE WALL INLET CUTOUT The wall inlet should be located 18 on cente...

Страница 5: ...imensions 4 Using the provided mounting screws secure the mounting bracket on the wall through two upper and two lower mounting holes 5 Hang power unit onto wall mounting bracket Ensure both upper and lower mounting openings on the back of the power unit are engaged with corresponding wall bracket fingers Pull the power unit down to secure 6 Open the door located on the front of the power unit Ens...

Страница 6: ... into a wall ceiling or concealed space in the house It is recommended to vent the vacuum exhaust air to the outside of the house Exterior vented exhaust lines should be terminated using Model V142 wall caps DIMENSIONAL CHART EXHAUST B CENTER OF EXHAUST TO MOUNTING BRACKET HOLES A OVERALL HEIGHT C INTAKE AD0004A Models VX3000C VX6000C VX12000C A 369 16 399 16 399 16 B 11 11 11 C 107 8 107 8 107 8 ...

Страница 7: ... 5 depending on the model No adapter should be used with this appliance TO OTHER INLETS NOTE INLET LEADS TO BE CONNECTED TO POWER UNIT TERMINALS USING CRIMP CONNECTORS AND LOW VOLTAGE WIRE HARNESS INLET LEADS MODEL V133 18 2 WIRE POWER UNIT POWER CORD NORTH AMERICA AC ELECTRIC OUTLET GROUND PIN NEMA 6 20R 240 VOLT GROUNDED OUTLET BOX AE0010A CRIMP CONNECTORS LOW VOLTAGE WIRE LOW VOLTAGE WIRE HARNE...

Страница 8: ... 3 AO0022 OPERATING HANDLE SWITCH LOW VOLTAGE HOSE The switch will turn power unit ON OFF DUAL VOLTAGE HOSE Switch on the right position Central vacuum mode with power brush Switch on the left position Central vacuum mode without power brush Switch in the center Power unit is turned OFF AD0025 A A AD0026 AD0033 AD0032 CONNECTING HOSE CONT D DUAL VOLTAGE HOSE In addition to connecting into wall inl...

Страница 9: ...K BUTTON HOSE HANDLE PRONGS WAND WAND RECEPTACLE RECEPTACLE WAND GRIP WAND RELEASE PEDAL POWER BRUSH NECK RELEASE PEDAL HOSE HANDLE RELEASE BUTTON QUICK CONNECTOR AO0019 AO0020 AO0021 WAND AND HOSE COMPATIBILITY WAND PART NO 08949 VACUUM HOSE PART NOS 32DVB 32DVN AND BN32DV HOSE HANDLE CAUTION Always check underside of product for any obstructions prior to use WARNING Never leave electric power br...

Страница 10: ...er that protects the motor and the belt if a too large object is picked up accidentally If the power brush stops while vacuuming turn the power unit off using handle Release the power brush from the wand and turn it over to see if there is an obstruction When brush roll jam has been cleared press the reset button H and connect the power brush back to the wand Finally turn the power unit power brus...

Страница 11: ... HOW TO CHANGE BRUSH ROLL Replace brush roll when brush roll brissles are worn to the base support bars level 1 Turn power brush over and using a Phillips no 2 screwdriver remove the 3 brush roll cover retaining screws Fig 6 and set aside 2 Remove brush roll cover Fig 7 3 To free brush roll from base start by sliding the belt side end and pull brush roll sideways 1 Once disengaged from housing lif...

Страница 12: ...t turns red it is time to empty the pail see CONTROL PANEL DIAGRAM A below EMPTYING THE DEBRIS PAIL Your power unit has a permanent filter that is self cleaning under normal conditions The filter protects the motor and stops small dirt particles from escaping to the outside of the power unit The filter cleans itself by moving up when the power unit starts and dropping down when the unit is turned ...

Страница 13: ...ptying the debris pail Simply brush filter clean If the filter is excessively soiled wash in a mild detergent and let it dry completely before reinstalling A FILTER REMOVAL Open the door located on the front of the power unit Reach inside the unit and remove both locking sleeves from the retaining hooks Carefully pull filter down to remove NOTE Broan model VX12000C has two secondary filters Ensure...

Страница 14: ...ck all wall inlet covers to be sure they are closed and sealed tightly Inspect and remove any blockages 2 Power unit does not start or shuts off during normal operation with no LED showing red or illuminated Defective inlet Check other wall inlets Thermoprotector has been activated OR there is a tripped circuit breaker on the unit Blown fuse or tripped circuit breaker on house electrical panel Def...

Страница 15: ...filter TS X X 8 10941217 Motor Chamber VS with foam and logo X 10941218 Motor Chamber TS with foam and logo X X 9 10941211 Top cap VS with logo X 10941213 Top cap TS with logo X X NOTE Order service parts by Part No not by Key No This part MUST be removed and installed by a qualified technician SERVICE PARTS REPLACEMENT PARTS AND REPAIRS In order to ensure your ventilation unit remains in good wor...

Страница 16: ... REPAIR OR REPLACE AT BROAN NUTONE CANADA S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Please do not return your unit to place of purchase Please visit www broan ca for your closest service center You may also cal...