1. The occupancy sensor wall switch turns lighting or fan loads on 

and off based on occupancy and ambient light level. They are 

designed to replace a standard light switch. The switch operates 

with 120 to 277V AC line voltage.

2. The sensor uses passive infrared technology to sense human 

motion, and defines it as occupancy. A red LED in the sensor 

blinks upon occupancy and then resets. It will blink again when 

it detects motion after the 2-second reset.

3. In Automatic ON & Automatic OFF mode, the sensor turns on 

the load automatically when it detects occupancy. Once the 

space is vacant and the time delay elapses, it turns off the load 

automatically.

4. If adequate ambient light is already present in the area, the 

sensor will hold off the load it controls. When the light drops 

below a field selectable level and the sensor detects occupancy, 

the sensor turns on the load. 

MOUNTING LOCATION

The device responds to temperature changes and care should be 

taken when mounting the device. Do not mount directly above a 

heat source, in a location where hot or cold drafts will blow 

directly on the sensor, or where unintended motion (e.g., hallway 

traffic) will be within sensor’s field-of-view. 

4A - INSTALLATION FOR SINGLE POLE

 

Slotted / Phillips Screwdriver

Pencil

PREPARATION BEFORE INSTALLATION

Single-Pole

1. Line (Hot)
2. Neutral
3. Ground
4. Load

Two Location Control

1. Line (Hot)
2. Neutral
3. Ground
4. Traveler (note color)
5. Load

1

2

3

4

1

3

4

5

2

If the wiring in the wall box does not resemble any of these 

configurations, consult an electrician. 

4. Before Wiring the Device:

1. Make sure that the ends of wires from the wall box are straight 

(cut if necessary). 

2. Remove 5/8" (1.6 cm) of insulation from each wire in the wall box.
3. Use wire connectors to join one 12 AWG supply wire with one or 

two 16 AWG or 18 AWG, or to join one 14 AWG supply wire with 

one to three 16 AWG or 18 AWG.

NOTE: Three wire connectors provided in the product 

package are suitable for copper or copper clad wire only.

For single-pole applications, go to Step 4A.
For two location control applications, go to Step 4B. 

Electrical Tape

Pliers

Cutters

Ruler

1. Turn OFF Power:

Turn power OFF at circuit breaker (or remove fuse).

2. Remove Wallplate and Switch:

Remove wallplate and switch mouting screws. Carefully 

remove switch from wall (do not remove wires).

3. Identify the Type of Circuit:

TOOLS NEEDED FOR INSTALLATION

UNIT FEATURES AND DESCRIPTION

WARNINGS AND CAUTIONS

1. 

CAUTION: 

To avoid overheating and possible damage to this 

device and other equipment, 

DO NOT

 install to control a 

receptacle.

2. To be installed and/or used in accordance with appropriate 

electrical codes and regulations.

3. If you are unsure about any part of these instructions, consult an 

electrician.

4. Use this device with copper or copper clad wire only.
5. Do not use this product to control loads in excess of specified 

ratings, or it may cause death, injury or property damage.

6. The sensing switch requires an unobstructed view of room 

occupants to detect motion.

7. Hot objects or moving air currents can affect the performance of 

the sensing switch.

8. For indoor use only. Operate between 32 to 104 

o

F (0 to 40 °C).

9. Clean sensor with a piece of soft damp cloth only. Do not use 

any chemical cleaners.

Hot (Black)

Black

Black

White

Line 120VAC, 60HZ

Green Ground

Neutral (White)

Load

Connect wires per wiring diagram as follows:

1. Connect green ground or bare copper wire in the wall box to the 

Green wire of the device.

2. Connect Hot wire in the wall box to the Black wire of the device.

3. Connect Load wire(s) in the wall box to the Red wire of the 

device.

4. Screw wire connectors on clockwise making sure no bare 

conductors show below the wire connectors. Secure each 

connector with electrical tape.

5. Mount device in the wall box with screws and mount wall plate.

6. Restore power at circuit breaker or fuse. Installation is complete.

7. Turn on the power, manually press the switch button to check 

whether the product is installed correctly, and at the same time 

ensure that the LED light in the fresnel lens flashes. Wait about 

40s for product booting, the product will work properly.

Green

Black

Red

Ground

Neutral

Hot

Load

Insert wires into 

wire connectors 

then twist 

clockwise

Use electrical 

tape to secure 

wire connectors 

and wires

Red

NOTE: 

1. A ground connection is required to operate. Use the ground 

wire in the wall box for ground connection. If no ground is 

available, consult an electrician. Device will not function if it is 

not grounded.

2. The hot (black wire) and load (red wire) must be correctly 

connected as stated above, otherwise the device will not 

function. If the light never turns on, then try to reverse the hot 

and load wiring of the sensor.

Passive Infrared Occupancy Sensor Wall Switch 

LED/CFL 300W, Incandescent 600W, 1/2 HP, 120~277VAC, 60Hz

INSTALLATION INSTRUCTIONS

Model No.:  

MS100W (Occupancy Sensor) 

Содержание NuTone MS100W

Страница 1: ...y the Type of Circuit TOOLS NEEDED FOR INSTALLATION UNIT FEATURES AND DESCRIPTION WARNINGS AND CAUTIONS 1 CAUTION To avoid overheating and possible damage to this device and other equipment DO NOT install to control a receptacle 2 To be installed and or used in accordance with appropriate electrical codes and regulations 3 If you are unsure about any part of these instructions consult an electrici...

Страница 2: ...nnection If no ground is available consult an electrician Device will not function if it is not grounded 4 The hot black wire and load red wire must be correctly connected as stated above otherwise the device will not function If the light never turns on then try to reverse the hot and load wiring of either or both sensors Disable Automatic OFF function Automatically turn off the light after 30 se...

Страница 3: ...LLATION CARACTÉRISTIQUES MISES EN GARDE 1 ATTENTION Pour éviter de surchauffer et possiblement d endommager l appareil et d autres pièces d équipement NE PAS l installer pour commander le circuit d une prise de courant 2 Cet appareil doit être installé et utilisé conformément aux codes et aux règlements locaux applicables 3 En cas de doute sur un aspect des instructions consulter un électricien 4 ...

Страница 4: ... pas de fil de mise à la terre consulter un électricien 4 La phase fil noir et la charge fil rouge doivent être bien connectées conformément aux instructions ci dessus pour que l appareil fonctionne Si l éclairage ne s allume jamais essayer d inverser les fils de phase et de charge de l un ou des deux détecteurs Fonction d arrêt automatique désactivée Arrêt automatique après 30 secondes Arrêt auto...

Страница 5: ...TERÍSTICAS Y DESCRIPCIÓN DE LA UNIDAD ADVERTENCIAS Y PRECAUCIONES 1 PRECAUCIÓN Para evitar el sobrecalentamiento y posibles daños a este dispositivo y otros equipos NO instale para controlar un receptáculo 2 Para ser instalado y o utilizado de acuerdo con los códigos y regulaciones eléctricas correspondientes 3 Si no está seguro acerca de alguna parte de estas instrucciones consulte a un electrici...

Страница 6: ...liente cable negro y la carga cable rojo deben estar correctamente conectados como se indicó anteriormente de lo contrario el dispositivo no funcionará Si la luz nunca se enciende intente invertir el cableado de carga y encendido de uno o ambos sensores Desactivar la función de apagado automático Apaga automáticamente la luz después de 30 segundos Apagar automáticamente la luz después de 5 minutos...

Отзывы: