8
3. MAINTENANCE (
CONT
’
D
)
3.2 A
NNUAL
M
AINTENANCE
(
FALL
)
Repeat steps 1 to 6 from the previous section and continue with the following steps:
1. Clean the heat recovery core:
• Remove
core.
•
Let it soak in a mixture of cold or lukewarm water and mild soap (dishwashing liquid).
• Rinse
thoroughly.
•
Shake the core to remove excess water and let it dry.
2. Clean blower assembly.
•
Remove dust using a vacuum cleaner with a soft brush attachment.
3. Reassemble the components.
4. Reconnect power supply.
CAUTION
Handle the heat recovery core with care.
4. TROUBLESHOOTING
P
ROBLEM
Y
OU
SHOULD
TRY
THIS
1. Nothing
works.
• See if the unit is plugged in.
• See if the unit is receiving power from the house
circuit breaker or fuse.
2. Noisy unit.
• Clean the unit (see Section 3). If the problem is not
solved, contact your installer.
3. Condensation on windows (air too
humid).
• Operate the unit at maximum speed (MAX.) during
activities generating excess humidity (family
gatherings, extra cooking, etc.).
• Leave curtains half-open to allow air circulation.
• Store all firewood in a closed room with a dehumidifier
or in a well ventilated room, or store the wood outdoors.
• Keep the temperature in your house above
18°C (64°F).
4. Air too dry.
• Operate the unit at low speed (MIN.).
•
Temporarily switch to the intermittent mode (if
available).
• Temporarily use a humidifier.
5. Air too cold at the air supply grille.
• Make sure the outdoor hoods are not blocked.
• Operate the unit at low speed (MIN.).
• Have the system’s balancing checked.
• Have the unit’s defrost system checked.
• Install a duct heater.
For wall controls problems, refer to the Troubleshooting section in the
Main and auxiliary wall
controls user guide
(included with the ventilation unit and also available at www.broan.com).