Once the diffusers location is determined, cut out 5¼” diameter hole.
Run one end of the flexible duct through the hole and fix it to the diffuser base (
1
),
using a tie wrap and duct tape. Assemble the diffuser base to the wall (or ceiling)
using its 4 no. 8 x 3/4” screws. Then, slide in the diffuser (
2
).
See illustration at right.
Ø 5¼”
VJ0094A
2
1
3. I
NSTALLATION
(
CONT
’
D
)
H
OW
TO
CONNECT
THE
FLEXIBLE
DUCTS
TO
THE
UNIT
PORTS
Both flexible ducts attached to the diffusers must be connected to the bottom ports of
the unit. When facing the unit door, the fresh air to building port is located on left side
and the exhaust air from building port is on the right side. Refer to the identification
labels affixed beside each unit ports. Using tie wrap, attach the fresh air to building
duct to its corresponding port, then do the same for the exhaust air to building duct
and port. See illustration at right.
NOTE: Use an insulated duct if the duct will have to go through a space where it is
possible to experience extreme temperature conditions (eg: in northern area,
unheated attic in winter or uncooled attic in southern area). Also, if you plan
to stop the unit for more than 12 hours, we recommend to cover the duct with
R12
insulation.
VJ0107
Aire de salida desde el interior
R
IGHT
SIDE
OF
THE
UNIT
Fresh air distribution ductwork
•
Install the fresh air distribution diffuser in a large, open area in the lowest level to ensure the greatest possible air circulation.
•
Keep in mind that the fresh air diffuser must be located as far as possible from the stale air diffuser. If desired, you can install
another
diffuser.
•
Install the diffuser either in the ceiling OR 6 to 12 inches (152 to 305 mm) from the ceiling on an interior wall. (The cooler air
will then cross the upper part of the room and mix with room air, before descending to occupant’s level.)
•
If a register must be floor installed, direct the airflow up the wall.
U
NIT
PORTS
IDENTIFICATION
Each unit port has an identification label
beside it to avoid wrong duct connections to
the unit. Always refer to these labels before
performing any duct and port connection.
VJ0106
Aire de salida hacia el exterior
Aire fresco hacia el interior
Aire fresco desde el exterior
Aire de salida desde el interior
UNIT
DOOR