background image

- 4 -

1. PREPARE THE INSTALLATION

2. INSTALL DUCTWORK AND ELECTRICAL WIRING

Plan where and how the ductwork will be installed. Access to the top of the hood is
preferred for connection of ductwork. 

Install 3¼” x 10” ductwork, elbows and roof or wall cap, according to the installation
type. Use 2” metal foil duct tape to seal duct joints.

NOTE:

Although the horizontal discharge installation is feasible, this installation type 
should be performed in specific situation only since it requires particular 
knowledge and technical skills from the installers.

The minimum hood distance above cooktop must not be less than 24”. 
A maximum of 30” above cooktop is recommended for best capture of cooking
impurities. 

Distances over 30” are at the installer and users discretion.

Run 3-wire power supply cable to installation location. Its length should extend at
least 4 feet below the bottom of the custom hood.

Power pack

Roof cap

Wall
cap

HH0119A

3

¼

 x 10

adapter & damper

24

 to 

3

0

above 
cookin

g

 

s

urface

3

¼

 x 10

 duct

T

YPICAL

D

UCTWORK

Make sure that the following items are included:
-  Power Pack
-  Accessories:

•  1 Filter
• 3¼” x 10” adapter and damper
• 2 Shielded halogen lamps (120 V, 50 W, MR16 with GU10 base)
• Bag of parts including: (1) wire clamp, (2) wire connectors, (4) no. 8 x 3/8” screws, 

(9) no. 8-10 x 1/2”, (8) no. 8-32 x 1/4” screws.

Parts sold separately:

-  Ducts, elbows, wall and roof caps. Refer to page 3 for a complete list of venting options and model numbers.
NOTE:

During installation, protect countertop and/or cooktop.

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

WARNING

!

Содержание BC2130SS

Страница 1: ...WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 10 AND 11 Broan NuTone Canada Inc Mississauga Ontario www broan ca 877 896 1119 www broan ca REGISTER YOUR PRODUCT ON LINE AT www broan com r...

Страница 2: ...orn Beef Flamb c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filters d Use proper pan size Always use cookware appropriate for the size of the surface elemen...

Страница 3: ...SS BC4130SS POWER PACK SYSTEM BC2130SS POWER PACK STANDARD 3 X 10 ROOF CAP NOT INCLUDED STANDARD 3 X 10 WALL CAP NOT INCLUDED 3 X 10 ADAPTER AND DAMPER INCLUDED STANDARD 3 X 10 DUCT NOT INCLUDED BC413...

Страница 4: ...stances over 30 are at the installer and users discretion Run 3 wire power supply cable to installation location Its length should extend at least 4 feet below the bottom of the custom hood Power pack...

Страница 5: ...filter 3 CUSTOM HOOD PREPARATION WARNING When building a custom hood always follow all applicable construction codes and standards The custom hood must be positively secured to wall studs or other wo...

Страница 6: ...le blower model this applies also for single blower model HD0360 A 7 UNPLUG THE BLOWER S Using a Phillips no 2 screwdriver remove the screw securing the blower plug cover in place Lift out the cover a...

Страница 7: ...TER DAMPER VERTICAL EXHAUST INSTALLATION The adapter damper will be installed on the back of the power pack once the power pack will be mounted in the custom hood Refer to step 15 HORIZONTAL EXHAUST I...

Страница 8: ...freely Wherever it is possible seal connections with metal foil duct tape CAUTION Take care not to kink ducting or pinch electrical cable when installing the power pack HD0362 HH0124 CLASPING SPRINGS...

Страница 9: ...TION Take care not to pinch wiring when reinstalling inner panel Carefully put back in place the inner panel Using a Phillips no 2 screwdriver and screws previously removed in step 8 secure the inner...

Страница 10: ...ng style generates more grease like frying foods or wok cooking Remove filter by pushing it towards the back of hood and rotating filter downward Filter is dishwasher safe Allow filter to dry complete...

Страница 11: ...repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESC...

Страница 12: ...R 1 5 SV01766 MOTOR LEFT 1 1 6 SV03400 BLOWER WHEEL LEFT 1 1 7 SV08965 SQUARE PATTERN FILTER 1 1 8 SV05921 SHIELDED HALOGEN LAMPS 120 V 50 W GU 10 2 2 9 SV16569 LIGHT SOCKET AND TRIM ASSEMBLY 2 2 10 S...