- 4 -
1. PREPARE THE INSTALLATION
2. INSTALL DUCTWORK AND ELECTRICAL WIRING
Plan where and how the ductwork will be installed. Access to the top of the hood is
preferred for connection of ductwork.
Install 3¼” x 10” ductwork, elbows and roof or wall cap, according to the installation
type. Use 2” metal foil duct tape to seal duct joints.
NOTE:
Although the horizontal discharge installation is feasible, this installation type
should be performed in specific situation only since it requires particular
knowledge and technical skills from the installers.
The minimum hood distance above cooktop must not be less than 24”.
A maximum of 30” above cooktop is recommended for best capture of cooking
impurities.
Distances over 30” are at the installer and users discretion.
Run 3-wire power supply cable to installation location. Its length should extend at
least 4 feet below the bottom of the custom hood.
Power pack
Roof cap
Wall
cap
HH0119A
3
¼
”
x 10
”
adapter & damper
24
”
to
3
0
”
above
cookin
g
s
urface
3
¼
”
x 10
”
duct
T
YPICAL
D
UCTWORK
Make sure that the following items are included:
- Power Pack
- Accessories:
• 1 Filter
• 3¼” x 10” adapter and damper
• 2 Shielded halogen lamps (120 V, 50 W, MR16 with GU10 base)
• Bag of parts including: (1) wire clamp, (2) wire connectors, (4) no. 8 x 3/8” screws,
(9) no. 8-10 x 1/2”, (8) no. 8-32 x 1/4” screws.
Parts sold separately:
- Ducts, elbows, wall and roof caps. Refer to page 3 for a complete list of venting options and model numbers.
NOTE:
During installation, protect countertop and/or cooktop.
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
WARNING
!