background image

Page 1

MODELS  764BN • 764RB • 764WH

DECORATIVE

 

VENTILATION FAN WITH LIGHT

READ AND SAVE THESE INSTRUCTIONS

WARNING  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufac-

turer. If you have questions, contact the manufacturer at 

the address or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at 

service panel and lock the service disconnecting means 

to prevent power from being switched on accidentally. 

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a 

tag, to the service panel.

3.  Installation work and electrical wiring must be done by 

a qualified person(s) in accordance with all applicable 

codes and standards, including fire-rated construction 

codes and standards.

4.  Sufficient air is needed for proper combustion and 

exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting. Follow the 

heating equipment manufacturer’s guideline and safety 

standards such as those published by the National Fire 

Protection Association (NFPA), and the American Society 

for Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not dam-

age electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  NEVER place a switch where it can be reached from a 

tub or shower.

8.  This unit must be grounded.
9.  This unit is U.L. listed. Type I.C. inherently protected.

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  This product is designed for installation in FLAT CEILINGS 

ONLY. Do not mount this product in a wall.

3.  The light fixture assembly must be mounted to the fan 

housing assembly included with this product. Do not 

mount the light fixture assembly to a wiring outlet box.

4.  To avoid motor bearing damage and noisy and/or unbal-

anced impellers, keep drywall spray, construction dust, 

etc. off power unit.

5.  Please read specification label on product for further 

information and requirements.

TYPICAL INSTALLATIONS

HOUSING MOUNTED

DIRECTLY TO JOIST

 

2x6 (or larger)  

Discharge parallel to joists.

HOUSING 

2 x 4 

CEILING 

JOIST or 

TRUSS 

MOUNTING 

TABS 

POWER CABLE 

ADDITIONAL 

FRAMING 

2 x 4 

CEILING 

JOIST or 

TRUSS 

CEILING 

MATERIAL 

GRILLE 

PAN 

GLASS

LIGHT SHADE

HOUSING MOUNTED

 

TO 2

x

4 TRUSS

Requires additional framing

for mounting tabs.

Discharge parallel to joists.

HOUSING MOUNTED

 

TO “I” JOIST

Requires additional framing 

for mounting tabs.

Discharge parallel to joists.

Installer: 

Leave this manual with the 

homeowner.
Homeowner: 

Use and Care information on page 4.

*

 Additional framing must be a 2x6 (minimum height).

*

*

SUSPENDED CEILINGS

Housing hung with wires - 

3-point mount.

PLAN THE INSTALLATION

The unit will operate 

most quietly and 

efficiently when 

located where the 

shortest possible 

duct run and 

minimum number 

of elbows will be 

needed.
Use a roof cap or 

wall cap that has a 

built-in damper to 

reduce backdrafts.
Plan to supply the 

unit with proper 

line voltage and 

appropriate power 

cable.

ROOF

CAP 

*

4-IN. ROUND

ELBOW(S) 

*

4-IN.

ROUND

DUCT 

*

WALL CAP 

*

*

 Purchase

   separately

INSULATION

(Can be placed 

around and over 

fan housing.)

FAN

HOUSING

Содержание 764BN

Страница 1: ...listed Type I C inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT C...

Страница 2: ...possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1...

Страница 3: ...L Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge...

Страница 4: ...to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or par...

Страница 5: ...rte que l on puisse l atteindre d une baignoire ou d une douche 8 Cet appareil doit tre reli une mise la terre 9 Cetappareilesthomologu U L TypeI C comporteuneprotection interne ATTENTION 1 Cet appare...

Страница 6: ...s et de coudes 2 Positionnez les brides de montage contre la solive de sorte que le bas du bo tier affleure la surface finie du plafond Positionnement dans des plafonds de 1 6 cm 5 8 po 2 5 cm 1 po et...

Страница 7: ...o tier dans l ouverture de sorte que son ar te inf rieure affleure la surface finie du plafond Clouez chaque bride la solive travers les trous en forme de serrure Pour assurer un fonctionnement silenc...

Страница 8: ...es nos 3 8 D 97015171 Ensemble de panneau de c blage comprend rep res nos 9 10 11 Veuillez commander les pi ces de rechange par N PI CE et non par N REP RE GARANTIE LIMIT E D UN AN BROAN NUTONE Broan...

Страница 9: ...ta unidad se debe conectar a tierra 9 Esta unidad est incluida en la lista de U L Tipo I C proteger inherente PRECAUCI N 1 Esta unidad debe usarse solamente para ventilaci n general No la utilice para...

Страница 10: ...uede al ras del cielo raso terminado Caracter stica adicional para la colocaci n en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubie...

Страница 11: ...redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a trav s de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que...

Страница 12: ...cita Algunos estados no permiten limitaci n a la duraci n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN NUTONE DE REPARAR O CAMBIAR A O...

Отзывы: