105
SOUND CVs
CV132
DC Sound Unit Shutdown (Turn-Off) Voltage
Description
This Value Sets the Decoders DC Sound Turn-Off Voltage
Values
0 to 255
Initial Value
62
Related CVs
Bit 7
Bit 0
0 0 1 1 1 1 1 0
The sound unit is instructed to play the shutdown effect and turn off
all effects at this value. The shutdown effect only plays from the idle
condition. Many factors contribute to what this actual voltage is such
as the power source, system volume, individual volumes (CV133,
CV135—CV156) and system loading. Lowering this value will
instruct the sound unit to play the shutdown effect at a lower voltage.
Note: Care should be taken with this value. Lowering this value
too low will result in the unit not being able to play the shutdown
effect and terminate all effects properly. The sound unit could
abruptly shut off. If this occurs, set this value to a larger number or
the initial value.