![Broadcom Emulex LPe12000 Series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/broadcom/emulex-lpe12000-series/emulex-lpe12000-series_installation-manual_2815604024.webp)
Broadcom
LPeHBAs-IG126-100
24
Emulex Host Bus Adapters
Installation Guide
Chapter 3: References
3.1 Specifications
3.1.1 LPe35000-Series HBAs
Table 16: LPe35000-Series HBA Specifications
Parameter
Range
Physical dimensions
LPe35000 HBAs and LPe35002 HBAs: low-profile form factor, 6.600 in. by 2.708 in.
LPe35004 HBAs: standard height, half-length form factor, 6.600 in. by 4.376 in.
Power requirements
Multimode optics (PCIe 3.0):
Single-channel LPe35000 HBAs: 8.8W (typical), 9.9W (maximum)
Duad-channel LPe35002 HBAs: 9.9W (typical), 11.0W (maximum)
Quad channel LPe35004 HBAs: 14.4W (typical), 15.9W (maximum)
Single-mode optics (PCIe 3.0):
Single-channel LPe35000 HBAs: 8.9W (typical), 10.1W (maximum)
Duad-channel LPe35002 HBAs: 10.2W (typical), 11.3 (maximum)
Quad channel LPe35004 HBAs: 15.0W (typical), 16.4W (maximum)
Multimode optics (PCIe 4.0):
Single-channel LPe35000 HBAs: 9.6 (typical), 10.7 (maximum)
Dual-channel LPe35002 HBAs: 10.7 (typical), 11.8 (maximum)
Single-mode optics (PCIe 4.0):
Single-channel LPe35000 HBAs: 9.7 (typical), 10.9 (maximum)
Dual-channel LPe35002 HBAs: 11.0 (typical), 12.1 (maximum)
Power susceptibility
The HBAs can operate within the following voltage ranges:
PCIe 12V: 12V ± 8%
Power supply noise susceptibility: 100 mV p-p at frequencies 100 kHz or less
Airflow
LPe35000 HBAs and LPe35002 HBAs: 200 linear feet per minute (minimum)
LPe35004 HBAs: 275 linear feet per minute (minimum)
Temperature
0°C to 55°C (operating)
–20°C to 85°C (storage)
NOTE:
Operating HBAs in higher temperature conditions might result in early failure.
Humidity
5% to 95% (noncondensing, 22°C wet bulb) for storage
10% to 90% (noncondensing, 22°C wet bulb) for operation
Содержание Emulex LPe12000 Series