24
Remote Unit
: Select the remote unit type. The available remote unit
types are
LBx without ICP
,
LBx with ICP
and
EAD/SCL with ICP.
Configure Key Action
The
Configure Key Action
page is used to configure the keys on the
virtual keypad. On the 8-key keypad, each function key can be defined
as a macro for up to 10 different actions. On the 16-key keypad, each
function key can be defined as a macro for up to 5 actions. The available
actions are Relay, RS-232, IR and Telnet. Digital Output actions are
only available if Digital IOs are configured as outputs in the
Configure
System
page.
On the top menu click
Configure
and then click
Key Action
. The
following page will be displayed:
Function Key
: Select the function key F1 through F8 to be defined.
Function Key Label
: Type in a label name for the selected function
key.
Function Key Mode
: Select
Standard
for a “momentary” type key.
Only one set of actions is assigned to a
Standard
key. Select
Toggle
for a “toggle” type key. A Toggle key has two states:
Press
and
Release
.