Broadata LBC-H-R-SCL-ICP Скачать руководство пользователя страница 17

LBC-H-R-SCL-ICP User Manual
Link Bridge

TM

 HBaseT Receiver with Inline Control Processor

Broadata Technical Support, (800) 214-0222

18

4.6

INFORMATION: Input, Output, Revision

INPUT:

 Input Resolution Displayed

OUTPUT:

 Output Resolution Displayed

REVISION:

 Firmware Revision Displayed

Содержание LBC-H-R-SCL-ICP

Страница 1: ...WITH INLINE CONTROL PROCESSOR BCI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use or application A...

Страница 2: ...om 3 SAFETY INSTRUCTIONS AND COMPLIANCE DECLARATIONS SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes surges electric...

Страница 3: ...8 2 3 ICP FRONT AND REAR PANEL 9 3 0 CONNECTOR PINOUT ASSIGNMENT 10 3 1 SCALING RECEIVER 10 3 1 1 IR PIN ASSIGNMENT 10 3 1 2 RS 232 PIN ASSIGNMENT 11 3 2 ICP 12 4 0 ON SCREEN DISPLAY OSD MENU 14 4 1...

Страница 4: ...and 1920x1200 60Hz High performance video scaler with OSD Menu Control Supports HDMI w embedded audio and optical audio extraction Provides output picture adjustment on contrast brightness hue satura...

Страница 5: ...6 Figure 1 1 shows a typical application diagram Figure 1 1 ORDERING INFORMATION LBC H R SCL ICP Link Bridge HDBaseT Scaling Receiver with Control I O Ports HDMI RS 232 IR LAN HDBaseT Link 1 CAT 5 6e...

Страница 6: ...ignal of this device only 3 OPTICAL OUT Connect to an amplifier or active speaker with optical cable for audio output 4 HDMI OUT This slot is to connect with HDMI TV Monitor 5 MENU Press this button t...

Страница 7: ...are listed in Appendix B 4 LAN Connect to an active network for LAN sharing of a total transmission rate up to 100Mbps Or when a compatible LAN equipped Transmitter is connected to an active network...

Страница 8: ...ansmitter and the Transmitter has connected with sources that shows image on screen 9 CAT5e 6 IN Connect to the Transmitter unit with a Single CAT5e 6 7 cable for receiving all data signals 2 3 ICP Fr...

Страница 9: ...Technical Support 800 214 0222 10 10 LAN Ethernet connector 11 RESET Press the button to reset the device back to factory default settings 3 0 CONNECTOR PINOUT ASSIGNMENT 3 1 Scaling Receiver 3 1 1 I...

Страница 10: ...ual Link BridgeTM HBaseT HDMI Receiver with Inline Control Processor Broadata Technical Support Sales Broadatacom com 11 3 1 2 RS 232 Pin Assignment Baud Rate 9600bps Data Bit 8 bits Parity None Flow...

Страница 11: ...elay 1 Normally Closed Reserved Do Not Connect Reserved Do Not Connect Digital I O LEDs 1 I O Ch 1 2 I O Ch 2 Remote LED On Remote IR TX LED On IR TX Act On High Level Reserved Do Not Connect Reserved...

Страница 12: ...IR OUT for external emitter IR detector behind holes Reset button push to reset to default settings RJ 45 1 TX 2 TX 3 RX 4 N C 5 N C 6 RX 7 N C 8 N C CONFIG Keypad 1 12V keypad power 2 RS 232 IN 3 RS...

Страница 13: ...UTPUT 640x480 60 800x600 60 1024x768 60 1360x768 60 1280x720 60 1280x800 60 1280x1024 60 1440x900 60 1400x1050 60 1680x1050 60 1600x1200 60 1920x1080 60 1920x1200 60 720x480P 60 1280x720P 60 Factory D...

Страница 14: ...0 1023 of Red Color Level GREEN 0 1023 of Green Color Level BLUE 0 1023 of Blue Color Level RED OFFSET 0 1023 of Red Color Level GREEN OFFSET 0 1023 of Green Color Level BLUE OFFSET 0 1023 of Blue Col...

Страница 15: ...LBC H R SCL ICP User Manual Link BridgeTM HBaseT Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 16 4 4 AUDIO VOLUME 0 100 DELAY OFF 40ms 110ms 150ms SOUND ON MUTE...

Страница 16: ...SCL ICP User Manual Link BridgeTM HBaseT HDMI Receiver with Inline Control Processor Broadata Technical Support Sales Broadatacom com 17 4 5 SETUP Factory Reset Keylock FACTORY RESET YES NO KEY LOCK...

Страница 17: ...geTM HBaseT Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 18 4 6 INFORMATION Input Output Revision INPUT Input Resolution Displayed OUTPUT Output Resolution Displayed...

Страница 18: ...IR code import A standard web browser can be used to access the web pages Accessing Web Server The IP address of the ICP must be obtained in order to access the Web Server There are 2 ways to obtain t...

Страница 19: ...top menu bar click Configure and then click System This brings up the ICP Login page In the ICP Login type in admin for the Userid and admin for the Password and then click Sign in button The Configur...

Страница 20: ...ata Technical Support Sales Broadatacom com 21 Configure System The Configure System page is used to configure the network keypad virtual keypad RS 232 channels Digital IO channels and remote unit typ...

Страница 21: ...ected to ICP Virtual Keypad Size Select 8 keys or 16 keys 8 keys option maximum of 10 actions per key 16 keys option maximum of 5 actions per key Auto Action Triggers Select Enable to enable the auto...

Страница 22: ...t Enable or Disable pull up resistor If the Digital IO Direction is set to Output there is an option for Digital Output Mode Digital Output Mode Select TTL for a 5V compatible TTL type output or Open...

Страница 23: ...key keypad each function key can be defined as a macro for up to 5 actions The available actions are Relay RS 232 IR and Telnet Digital Output actions are only available if Digital IOs are configured...

Страница 24: ...state Command Action Select the action number to be defined Action 1 through Action 10 can be defined Spacing Enter the delay desired before the command action Action Type Select the action type Avai...

Страница 25: ...Technical Support 800 214 0222 26 Digital Output Options Digital Output Channel Select the digital output channel 1 or 2 Note this option is not available if both Digital IO channels are set to Input...

Страница 26: ...Broadatacom com 27 RS 232 Options RS 232 Channel Select channel 1 2 3 or 3 Remote Transmit String Type in the text string to be transmitted Strings are terminated with CR or CR LF depending on the se...

Страница 27: ...Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 28 IR Options IR Preset Select from list of IR commands stored in memory IR commands must be learned via Configure IR Co...

Страница 28: ...Options Telnet ID Select the telnet connection desired for telnet actions The connections defined in Configure Telnet Connections page appear in this menu Commands Enter the command strings to be tra...

Страница 29: ...tion presses the key selected in Key Number menu All associated actions for the key press state will be executed Release This action releases the key selected in Key Number menu All associated actions...

Страница 30: ...igure and then click Auto Actions The following page will be displayed Trigger Select the auto action trigger Available triggers are Video Detect Digital Input 1 Digital Input 2 RS 232 Channel 1 RS 23...

Страница 31: ...of the IR code in New Label and click the Learn button Once IR Learn mode is initiated the user needs to present an IR signal to the IR receiver port within 30 seconds If a valid IR code is not presen...

Страница 32: ...ure IR Code Import page is used to import an IR pronto code Once a code is imported it will be stored in memory and is available as an IR Preset It can be tested in the Configure IR Code page On the t...

Страница 33: ...on The Persistent connection is a permanent telnet connection between the ICP and the remote device This type of connection is typically used for monitoring telnet status messages for the purpose of t...

Страница 34: ...red for log in Leave blank if there is no username Password Prompt Enter password prompt from telnet server Leave blank if there is no password prompt Password Enter password required for log in Leave...

Страница 35: ...on next to Key Action Definitions to display the Key Action settings details Click the Details button next to Auto Action Definitions to display AutoAction settings details Click the Details button ne...

Страница 36: ...P User Manual Link BridgeTM HBaseT HDMI Receiver with Inline Control Processor Broadata Technical Support Sales Broadatacom com 37 Click the Key Action Definitions Details button and the following wil...

Страница 37: ...SCL ICP User Manual Link BridgeTM HBaseT Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 38 Click the Auto Action Definitions Details button and the following will be di...

Страница 38: ...CP User Manual Link BridgeTM HBaseT HDMI Receiver with Inline Control Processor Broadata Technical Support Sales Broadatacom com 39 Click the IR Code Definitions Details button and the following will...

Страница 39: ...R SCL ICP User Manual Link BridgeTM HBaseT Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 40 Click the Telnet Definitions Details button and the following will be disp...

Страница 40: ...cal Support Sales Broadatacom com 41 Examples Example 1 This example configures the F1 key on the virtual keypad as a toggle key to turn on off Relay channel 1 On the top menu click Configure and then...

Страница 41: ...ver with Inline Control Processor Broadata Technical Support 800 214 0222 42 Configure F1 Key toggle release action to turn Relay channel 1 Off as follows Click Submit Changes On the top menu click Ke...

Страница 42: ...200 60Hz Connector HDMI Female Plug Protocols DDC EDID HDCP Capable Supported Resolutions Resolution Vertical Refresh Rate Hz 640x480 60 800x600 60 1360x768 60 1280x720 60 1280x800 60 1280x1024 60 144...

Страница 43: ...Ds Data Rate 10 100Base T half full duplex with autodetect Protocols DHCP HTTP TCP IP UDP IP AUTOIP Telnet RS 232 Control Channel Capacity 2 no flow control or 1 with RTS CTS flow control Baud Rate 24...

Страница 44: ...ck for IR blaster Carrier Frequency 30 kHz to 60 kHz Output 30 kHz to 60 kHz IR learning IR Learning 2 inches captive distance from panel Relay Control Channel Capacity 2 normally open normally closed...

Страница 45: ...H R SCL ICP System contains no user serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please contac...

Страница 46: ...and do not include malfunctions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage...

Страница 47: ...LBC H R SCL ICP User Manual Link BridgeTM HBaseT Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 48 9 0 APPENDIX RS 232 COMMANDS FOR SCALING RECEIVER...

Страница 48: ...om 49 Note 1 RS 232 commands will not execute unless followed with carriage return and LF Line Feed 2 Commands are not case sensitive 3 Resolutions 1 16 are RGB encoded and 17 25 are YUV encoded 4 Dig...

Страница 49: ...LBC H R SCL ICP User Manual Link BridgeTM HBaseT Receiver with Inline Control Processor Broadata Technical Support 800 214 0222 50...

Страница 50: ...LBC H R SCL ICP User Manual Link BridgeTM HBaseT HDMI Receiver with Inline Control Processor Broadata Technical Support Sales Broadatacom com 51...

Страница 51: ...ta Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail CustomerService Broadatacom com Website www broadatacom com 60000 LBCHR...

Отзывы: